Smeg STA643PQ User instructions, E7 E8 E9, Fault, Description, Turbine flow-regulator malfunction

Models: STA643PQ

1 39
Download 39 pages 661 b
Page 37
Image 37
E7

E7

E8

E9

36

User instructions

FAULT

DESCRIPTION

 

 

 

Turbine flow-regulator malfunction

 

(for the relevant models only)

 

The appliance is not able to "measure" the amount

 

of water loaded accurately. Interrupt the program

 

and switch off the dishwasher. Switch the

 

dishwasher back on, program it again and start

 

the washing cycle. If the problem persists, contact

 

the after-sales service.

 

 

 

Alternate washing system malfunction

 

Interrupt the program and switch off the dishwasher.

 

Switch the dishwasher back on, program it again and

 

start the washing cycle. If the problem persists,

 

contact the after-sales service.

 

 

 

Water intake system malfunction

 

Contact the after-sales service.

 

 

Light off

Light on

Light flashing

If an alarm occurs the appliance interrupts the program in progress and signals a fault.

Alarms E1, E2, E3, E4, E8 and E9 interrupt the current program immediately.

The E5, E6 alarms interrupts the running program once the cause is resolved, it will bring bach the execution of the program.

The alarm E7 is visualized at the end of the cycle that comes, however, brought to the end since the operation of the dishwasher is not harmed.

To “reset” an alarm is necessary:

Open and close the door, or turn off and on the machine. At this point is possible to program the dishwasher again.

If the malfunction persists, contact your authorised Service Centre.