4. Maintenance

The osmosis treatment unit runs completely automatically and maintenance is minimal. The only essential operation is periodic replacement of the filter cartridges.

IMPORTANT

Replace the pre-filter every 3000 hours of operation and AT LEAST 1 time a year.

Pre-filter Membrane

Replacing the pre-filter:

Filter cartridge replacement procedure

-Shut off power;

-Close the side cocks (RL);

-Vent the circuit from the top cap (S);

-Unscrew the filter housing (use the special wrench supplied in the accessories bag). Place a container to drain the water in the filter into;

-Fit the new cartridge and check it is correctly seated;

-Close vent S and open the side cocks RL;

-Check for leaks and water in the bottom of the appliance;

-Dry it off thoroughly.

Replacing the membranes:

Cartridge replacement procedure.

-Shut off power;

-Disconnect all hoses from the membrane housings, unscrew the base, and place a container to catch the water contained in the cartridges;

-Refit the membrane, check the seating of the o-ring and screw the housing fully in; reconnect the hoses and make sure they are correctly seated;

-Do not apply excessive force;

-Fit the new cartridge and check it is correctly seated;

-Start the unit up and check for leaks.