ENGLISH

Messages

The scale sets the value zero automatically when it is switched on.

The zero range at power- on is -5% ....+15% of the

weighing range.

If the scale is outside the set tolerance range, the display shown adjacent appears.

Elimination

Either take the load off the platform or press the

key to activate the cali- brated zero point.

There is a mechanical or electrical fault.

77mm

82,6 mm

125 mm

306 mm

Parts weight too small

The scale is not suitable

for these parts.

 

Zeroing not possible

The zero limit has been

exceeded or undershot.

 

Taring is not possible

Cannot tare the zero

display or negative values.

 

Print not permitted on

Place an object on the

scale / remove an object

over- or underload

from the scale.

 

Switch to lbs

Activation is described on

deactivated

Pages 18/19.

 

In case of other error mes-

 

sages, please contact your

 

SOEHNLE service

Technical data

Housing made of anodised aluminium

Protection class IP 65, dust-proof and splash-proof.

Operated by means of a tactile keypad.

Plug-in power supply 100-240V, 57-63Hz

Operating temperature -10° ..... +40° C

Storage temperature -20° ..... +60° C

Zero range -1 %... +3 % of the weighing range (max.)

Zero range at power-on -5% ...+15% of the weighing range.

RS 232 (V24) interface for printer or IT connection. For a description of the interface, please contact your Soehnle service partner.

20

143,7 mm

Page 20
Image 20
Soehnle 2790 manual Messages, Elimination, Technical data