USING YOUR AIR CONDITIONER (Cont.)

Freezing Conditions: This is a cooling only air conditioner. It is not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions.

Remote Control: To ensure proper operation when using the remote control, aim the remote directly at the signal receiver on the air condi- tioner.

The remote control has a signal range up to 20 feet.

Make sure nothing is blocking the remote con- trol signal from being received by the air con- ditioner.

Make sure the batteries are installed correctly and still have power.

Cooling Mode: Use the COOL mode at Low, Me- dium, High, or Auto Fan speed when cooling is needed. Use the temperature ▲/▼ buttons to set the desired temperature between 64°F and 86°F.

Once the temperature is set, the compressor will cycle on and off to keep the room temperature at the set temperature level. The lower the set thermostat temperature, the cooler the room will become. The higher the set thermostat temperature, the warmer the room will become.

For Normal Cooling - Set the Mode to Cool and the Fan to High or Med with the termperature set in the middle.

For Maximum Cooling - Set the Mode to Cool and the Fan to High with a lower set temperature.

For Quieter & Nighttime Cooling - Set the Mode to Cool and the Fan to Low with the temperature set in the middle.

NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.

Energy Saver Mode - Controls the Fan

On - The fan will cycle on and off with the compressor. This results in winder variations of room temperature and humidity. Normally used with the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.

Off - The fan runs all the time in fan or cooling mode.

Fan Only Mode: Use Fan Only mode at Low, Med, or High fan speed to provide air circulation and filtering without cooling. Since fan only setting do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.

NOTE: Auto Fan Speed cannot be used in Fan Only mode.

Loss of Power Protection: If power to the air conditioner is lost or interrupted, the air condi- tioner will automatically re-start in the setting last used prior to power loss. If the Timer was set to automatically turn the air conditioner off or on, it will resume countdown at the amount time left prior to power loss. You may need to set a new time if desired.

Air Direction: Use the lever on the front air vents to adjust the direction of the airflow. You can di- rect the airflow left, right, up or down. The lever is located on the right side of the air vent.

17

Page 18
Image 18
Soleus Air GM-WAC-25ESE-C manual Using Your AIR Conditioner

GM-WAC-25ESE-C specifications

The Soleus Air GM-WAC-25ESE-C represents a significant advancement in window air conditioning technology, designed to provide efficient cooling in a variety of spaces. With a focus on energy efficiency and user-friendly features, this unit is a popular choice for residential and commercial applications alike.

One of the standout features of the GM-WAC-25ESE-C is its impressive cooling capacity. With a powerful 25,000 BTU rating, it effectively cools areas of up to 1,500 square feet, making it ideal for larger rooms or open floor plans. This high capacity is complemented by a range of fan speeds, allowing users to customize their cooling experience based on their needs.

Energy efficiency is a key characteristic of this model, boasting an Energy Efficiency Ratio (EER) that meets or exceeds industry standards. This enables users to enjoy a comfortable environment without incurring exorbitant electricity bills. The unit is also equipped with an Energy Saver mode, which automatically adjusts the cooling output to maintain the desired temperature while conserving energy.

Another technological feature of the Soleus Air GM-WAC-25ESE-C is its user-friendly remote control. This allows for easy adjustments from anywhere in the room, adding to the convenience of the unit. The air conditioner also includes a programmable timer, giving users the flexibility to set operation times that fit their schedules, further enhancing energy efficiency.

The dual motor design of the GM-WAC-25ESE-C offers improved airflow and more consistent cooling. This technology helps reduce temperature fluctuations, ensuring a more stable and comfortable indoor climate. Additionally, the unit features multiple modes, including dehumidification and fan-only modes, providing versatility for different weather conditions.

Installation is made simple with the included window kit, allowing for a straightforward setup process. The unit is also designed with a washable air filter, which not only helps maintain air quality but also extends the lifespan of the unit. Regular maintenance is made easy, contributing to its overall longevity.

In conclusion, the Soleus Air GM-WAC-25ESE-C stands out as a powerful, energy-efficient window air conditioner that combines advanced technologies with user-friendly features. It's an excellent choice for anyone looking to cool larger spaces while keeping energy use and costs to a minimum.