ELECTRICAL REQUIREMENTS

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove the ground prong. Do not use an adapter

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock

The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front).

Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord.

Power Supply Cord

NEMA 6-20P

Recommended Ground Method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus- tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.

It is the customer’s responsibility:

Copies of the standards listed may be obtained from:

To contact a qualified electrician

National Fire Protection Association

To assure that the electrical installation is adequate

One Batterymarch Park

Quincy, Massachusetts 02269

and in conformance with the National Electrical Code,

ANSI/NFPA 70 - latest edition, and all local codes and

 

ordinances.

 

 

 

LCDI Power Cord and Plug

 

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that is required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged and leakage occurs, power will be disconnected from the unit.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:

1.Plug power cord into a grounded 3 prong outlet

2.Press RESET (on some units a green light will turn on).

3.Press the TEST Button, the circuit should trip and cut all power to the air conditioner (on some units a green light may turn off.

4.Press the RESET button for use. You will hear a click and the A/C is not ready for use.

NOTES:

The RESET button must be engaged for proper use.

The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset.

Do not use the power supply cord as an ON/OFF switch. The power supply cord is designed as a protection device.

A damaged power supply cord must be replaced with a new power supply cord from Soleus Air Powered by Gree.

The power supply cord contains new user serviceable parts. Opening the tamper-resistant case voids all warranty and per- formance claims.

NOTE: Your units power cord and plug may differ from the one shown.

3

Page 4
Image 4
Soleus Air GM-WAC-25ESE-C manual Electrical Requirements, Recommended Ground Method, Lcdi Power Cord and Plug

GM-WAC-25ESE-C specifications

The Soleus Air GM-WAC-25ESE-C represents a significant advancement in window air conditioning technology, designed to provide efficient cooling in a variety of spaces. With a focus on energy efficiency and user-friendly features, this unit is a popular choice for residential and commercial applications alike.

One of the standout features of the GM-WAC-25ESE-C is its impressive cooling capacity. With a powerful 25,000 BTU rating, it effectively cools areas of up to 1,500 square feet, making it ideal for larger rooms or open floor plans. This high capacity is complemented by a range of fan speeds, allowing users to customize their cooling experience based on their needs.

Energy efficiency is a key characteristic of this model, boasting an Energy Efficiency Ratio (EER) that meets or exceeds industry standards. This enables users to enjoy a comfortable environment without incurring exorbitant electricity bills. The unit is also equipped with an Energy Saver mode, which automatically adjusts the cooling output to maintain the desired temperature while conserving energy.

Another technological feature of the Soleus Air GM-WAC-25ESE-C is its user-friendly remote control. This allows for easy adjustments from anywhere in the room, adding to the convenience of the unit. The air conditioner also includes a programmable timer, giving users the flexibility to set operation times that fit their schedules, further enhancing energy efficiency.

The dual motor design of the GM-WAC-25ESE-C offers improved airflow and more consistent cooling. This technology helps reduce temperature fluctuations, ensuring a more stable and comfortable indoor climate. Additionally, the unit features multiple modes, including dehumidification and fan-only modes, providing versatility for different weather conditions.

Installation is made simple with the included window kit, allowing for a straightforward setup process. The unit is also designed with a washable air filter, which not only helps maintain air quality but also extends the lifespan of the unit. Regular maintenance is made easy, contributing to its overall longevity.

In conclusion, the Soleus Air GM-WAC-25ESE-C stands out as a powerful, energy-efficient window air conditioner that combines advanced technologies with user-friendly features. It's an excellent choice for anyone looking to cool larger spaces while keeping energy use and costs to a minimum.