HEATER LOCATION AND INSTALLATION
Install the heater out of traffic areas maintaining the required clearances below. The direction of air flow shold not be restricted by anything and the air flow should not blow directly at exposed walls. When more than one heater is used in an area, the heaters should be arranged so that the air discharge of each heater supports the air flow of the other heater(s) to provide optimal circulation of warm air
DIAGRAM 1
15.7”
14.37”
Note: Min. clearance to ceiling when not using mounting brackets is 1 5/8”
FRONT VIEW
MINIMUM
DISTANCE
TO WALL
13”
11.29”
5 1/2”
24”
MINIMUM
MOUNTING DISTANCE
LOCATIONFROM DISCHARGE TO
ANY OBJECT
MINIMUM
DISTANCE TO
FLOOR 6 ft.
MAXIMUM MOUNTING HEIGHT FOR:
Vertical air delivery unit = 11 ft. Horizontal air delivery unit = 8 ft.
SIDE VIEW
6