Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Proper installation is your responsibility. Make sure you have everything necessary for correct installation.

The location should provide:

Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner.

NOTE: Do not use an extension cord.

Free movement of air in room to be cooled.

A large enough opening for the air conditioner. Installation parts are supplied for double-hung windows.

Adequate wall support for weight of air conditioner. Air conditioner weighs 51 lb (23 kg) to 65 lb (29.5 kg).

NOTES:

Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.

Your model may differ from the one shown.

A

A. Cabinet louvers

Window Installation

Window opening measurements:

o25" (63.5 cm) minimum to 38" (96.5 cm) maximum opening

width

o14" (35.6 cm) minimum opening height

A

B

A. 25" (63.5 cm) minimum

B. 14" (35.6 cm) minimum

4

Electrical Requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located behind the front panel above the coil area.

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power supply cord

Wiring requirements

o 115 volt (103.5 min.-

 

126.5max.)

o

0-12 amps

o 15-amp time-delay fuse or circuit breaker

o Use on single outlet circuit only.

Page 4