◆Specifications and Technical Data
| Model |
| |
|
|
|
|
Function |
|
| Heating and Cooling |
Cooling capacity(BTU/hr) & (Watts) | 22000 / 6450 | ||
Heating capacity(BTU/hr) & (Watts) | 24200 / 7100 | ||
|
|
|
|
Rated voltage |
|
| |
Rated Frequency |
|
| 60Hz |
|
|
| |
Cooling/Heating rated current(A) | 10.0/9.3 | ||
Cooling/Heating rated power(W) | 3300/3200 | ||
|
|
| |
Cooling/Heating power input(W) | 2280/2250 | ||
|
|
|
|
SEER |
|
| 14 |
EER/COP(W/W) |
| ||
|
|
|
|
HSPF |
|
| 8.4 |
Recycling Air Volume(m3/h) | 1100/1000/900 | ||
Factory Charge 410A (lbs.)* | R410A 5.3 lbs | ||
|
|
| |
Noise (Indoor/Outdoor) dBA | 50/59 | ||
Height |
| Maximum Vertical |
|
Differential |
| Maximum Length |
|
Net Weight (Indoor/Outdoor) (lbs) | 38.6/138.9 | ||
|
| ||
Dimensions (Indoor/Outdoor) | Indoor unit :46.38” × 8.98” ×12.83” | ||
(WxDxH)(inch) |
|
| Outdoor unit:37.40” × 16.54” × 33.07” |
Connection Pipe:
Length (ft) |
| 26.25 | |
Gas additional charge(oz/ft) |
| 0.21 | |
Outer Diameter | Liquid Pipe (mm) | Φ9.52(3/8”) | |
Gas Pipe (mm) | Φ16(5/8”) | ||
| |||
Max Distance | Height (ft) | 32.81 | |
Length (ft) | 65.62 | ||
|
1. All above are tested and certified to ETL specification.
2. All above could be changed without notice; the latest specifications are on the nameplate of your air conditioner.
When the unit is restarded after it stopping, it can automatically resume the last running mode, and the outdoor unit starts later.
Working temperature range
|
| Indoor side DB/WB(°F) | Outdoor side DB/WB(°F) |
|
| Maximum cooling | 90 / 74 | 109 / 79 |
|
| Minimum cooling | 70 / 59 | 70 / |
|
| Maximum heating | 81 / | 75 / 64 |
|
| Minimum heating | 68 / | 23 / 21 |
|
|
|
|
|
|
|
| - 11 - |
|
|