Soleus Air service manual KFHHP-22-OD

Models: KFHHP-22

1 32
Download 32 pages 20.02 Kb
Page 3
Image 3

 

 

Model of Outdoor Unit

KFHHP-22-OD

 

 

 

Compressor Model

C-6RZ146H1A

 

 

 

Compressor Type

Rotary

 

 

 

L.R.A. (A)

 

40

 

 

 

Compressor RLA(A)

8.4

 

 

 

Compressor Power Input(W)

1640

 

 

 

Overload Protector

1NT11L-3979

 

 

 

Throttling Method

Capillary throttling

 

 

 

Starting Method

Transducer starting

 

 

 

Working Temp Range (￿)

￿-10~43￿￿

 

 

 

Condenser

Aluminum fin-copper tube

 

 

 

Pipe Diameter (in)

φ0.3748

 

 

 

Rows-Fin Gap(in)

2-0.055

 

 

 

Coil lengthxheightxcoil width(in)

26.9X32X1.73

 

 

 

Fan Motor Speed (rpm)

780/600

 

 

 

Output of Fan Motor (W)

60

 

 

 

Fan Motor RLA(A)

0.25

 

 

Outdoor

Fan Motor Capacitor (uF)

3

 

Air Flow Volume of Outdoor Unit

/

 

 

unit

 

 

Fan Type-Piece

Axial fan –1

 

 

 

 

 

 

Fan Diameter (in)

φ18.11

 

 

 

Defrosting Method

Auto defrost

 

 

 

Climate Type

T1

 

 

 

Isolation

 

I

 

 

 

Moisture Protection

IP24

 

 

 

Permissible Excessive

 

 

 

 

Operating Pressure for the

4

 

 

 

Discharge Side(MPa)

 

 

 

 

Permissible Excessive

 

 

 

 

Operating Pressure for the

/

 

 

 

Suction Side(MPa)

 

 

 

 

Sound Pressure Level dB (A)

59/58

 

 

 

Dimension (W/D/H)( in)

37.4X16.22X33.07

 

 

 

Package Dimension(W/D/H)(in)

43.3X17.7X35.6

 

 

 

Net Weight /Gross Weight (lb)

141.1/152.1

 

 

 

Refrigerant Charge (oz)

R410a/84

 

 

 

 

 

 

 

 

 

Length (ft)

 

26.25

 

Connection

Outer

Liquid Pipe (mm)

Φ9.52(3/8”)

 

Diameter

Gas Pipe (mm)

Φ16(5/8”)

 

 

Pipe

 

 

Max

Height (ft)

40

 

 

 

 

 

 

Distance

Length (ft)

100

 

The data above is subject to change without notice .Please refer to the nameplate of the unit