Soleus Air KFHHP-22 service manual Operating procedures/pictures, Disassemblle capillary

Models: KFHHP-22

1 32
Download 32 pages 20.02 Kb
Page 22
Image 22

Operating procedures/pictures

Disassemblle capillary

Unsolder the joint points between capillary and other pipelines;them it can be removed

(Refer to figure 7-23)

capillary

 

Disassemble valves

Unsrew the two screws fixing the big valve;unsoldering the soldering points between the big valve and air-return duct;remove big valve (When unsoldering,use wet cloth to wrap the big valve completely to prevent it from being harmed by high temperature.

Unscrew the 2 screws fixing small valve;unsolder the joint points between small valve and fork type pipe;remove small valve

(Refer to figure 7-24)

small valve

screws

big valve

Disassemble compressor

Unsolder the soldering points between the pipes and compressor;unscrew

the three nuts with washers at the foot of compressor;take out the compressor

(Refer to figure 7-25)

compressor

 

 

compressor nuts

Figure

-22-