| drain hose is blocked or broken | replace the drain hose |
water leakage |
|
|
| connector of refrigerant pipe isn't wrapped well | wrap and tight it again |
|
| |
| indoor fan collides with other parts | adjust the location of fan |
| abnormal things in indoor unit | remove it |
|
| |
| compresoor shakes overly | adjust the washer and tight the bolt |
|
| |
abnormal shake | pipes in outdoor unit collides | set the pipes apart |
|
| |
or sound |
|
|
| metal plates collides | tighten the connecting bolt |
|
| |
|
| stick |
| outdoor fan collides with case | adjust the fan location |
| abnormal sound inside compressor | replace compressor |
| abnormal electromagnetic sound in | short circuit inside electromagnetic valve;repalace it |
| ||
|
| |
CAUTION: |
|
|
1,When repairing,before the voltage between module PN is measured below 50V,do not touch any terminal | ||
to avoid electrical shock |
| |
2,When replacing power module and rectifier,make sure to spread the indicating paste evenly | ||
|
|