drain hose is blocked or broken

replace the drain hose

water leakage

 

 

 

connector of refrigerant pipe isn't wrapped well

wrap and tight it again

 

 

 

indoor fan collides with other parts

adjust the location of fan

 

abnormal things in indoor unit

remove it

 

 

 

compresoor shakes overly

adjust the washer and tight the bolt

 

 

abnormal shake

pipes in outdoor unit collides

set the pipes apart

 

 

or sound

 

 

 

metal plates collides

tighten the connecting bolt

 

 

 

 

stick shake-reduction plaster between the metal plates

 

outdoor fan collides with case

adjust the fan location

 

abnormal sound inside compressor

replace compressor

 

abnormal electromagnetic sound in

short circuit inside electromagnetic valve;repalace it

 

4-way valve in HEAT mode

 

 

CAUTION:

 

 

1,When repairing,before the voltage between module PN is measured below 50V,do not touch any terminal

to avoid electrical shock

 

2,When replacing power module and rectifier,make sure to spread the indicating paste evenly

 

-30-

 

Page 30
Image 30
Soleus Air KFHHP-22 service manual Wrap and tight it again