D14

blink 6 times

blink 7 times

blink 8 times

D17

blink 1 time

blink 2 times

blink 3 times

blink 4 times

blink 5 times

blink 6 times

blink 7 times

blink 8 times

Meaning

Unit closing down for

min.frequency

Unit closing down for

PFC protection

Unit closing down for

compressor overloading

Meaning

too low DC input voltage

too high DC voltage

AC current protection

IPM abnormality

reserved built-in PFC

protection

start-up failure

phase-losing or out of

control

first PFC protection ;then

module protection

D15

blink 6 times

blink 7 times

blink 8 times

blink 9 times

D18

 

 

 

when no short-circuit in

On

computer monitor port

 

off

 

 

short-circuit in

blink

computer monitor port

 

 

 

 

not

 

blink

 

 

 

 

 

 

 

 

 

 

Meaning

frequency of current 12 A lasting for 2 minutes

frequency limiting or demultiplying for rate of

frequency variation out of control

frequency limiting or demultiplying of compressor

current

frequency limiting or demultiplying for over temp.of

IPM module

Meaning

receiving or sending indoor data

receiving or sending indoor data finished

normal communication between main borad and

driving board

abnormal communication between main board and

driving board

-14-

Page 14
Image 14
Soleus Air KFHHP-22 service manual D17