◆Test Operation and Check after Installation

Test Operation and Check after Installation

Test Operation

1.Before Test Operation

(1)Do not switch on power before installation is finished completely.

(2)Electric wiring must be connected correctly and securely

(3)Cut-off valves of the connection pipes should be opened.

(4)All the impurities such as scraps must be cleared from the unit.

2.Test Operation Method

(1)Switch on power and press “ON/OFF” button on the remote control to run the air conditioner.

(2)Press “MODE” button and check the operation condition of COOL, HEAT, SWING mode and so on.

If Wireless remote control is lost, open the surface panel and operate as following:

a.When turning it to Auto position, unit will run in Auto mode, if there is remote control signal, it will run at the remote control signal.

b.When turning it to Test position, the main unit will enter into Cool mode, indoor fan will run at high fan speed, if there is remote control signal, main unit will run at the remote control signal.

c.When turning it to Run position, the main unit will run at received remote control order.

d.When turning it to Stop position, the unit will stop running.

Check after Installation

Items to be checked

Possible Malfunction

 

 

Has it been properly mounted?

The unit may drop, shake or emit noise.

 

 

Have you done the refrigerant leakage test?

It may cause insufficient cooling (heating) capacity.

 

 

Does the unit drain well?

It may cause condensation and dripping.

 

 

Is the voltage in accordance with the rated

It may cause electric malfunction or damage the part.

voltage marked on the nameplate?

 

Is the electric wiring and piping connection

It may cause electric malfunction or damage the unit.

installed correctly and securely?

 

Has the unit been connected to secure grounding

It may cause electrical leakage.

connection?

 

Has the inlet and outlet been insulated?

It may cause insufficient cooling (heating) capacity.

 

 

Has the length of connection pipes and refrigerant

The refrigerant capacity is not accurate.

capacity been recorded?

 

- 17 -

Page 19
Image 19
Soleus Air KFHIP-09-OD Test Operation and Check after Installation, Before Test Operation, Test Operation Method