Soleus Air LX-140 manual Auto Mode, Compressor Indicator

Models: LX-140

1 18
Download 18 pages 8.17 Kb
Page 13
Image 13
Auto Mode

Auto Mode

1)Install the exhaust hoses and window kit properly (see pages 7 , 8 & 9 ).

2)Plug the Power Cord into an electrical outlet.

3)Turn on the unit by pressing the POWER button on the control panel.

4)Press the MODE button until the “ Compressor Indicator ” icon appears on the control panel display. Select the fan speed by pressing the FAN button.

NOTE: During AUTO mode, the unit operates in Heating mode when the room temperature is below 68 °F, Dehumidifier mode when the room temperature is between 68 °F to 80 °F. And Air Conditioner mode when the room temperature is above 80 °F.

Sleep Mode (This mode can only be selected when using the Remote control )

1)To set Sleep mode, make sure the unit is in Air Conditioner mode or Heating mode .

2)Press the SLEEP Button on the remote control. The “ Manual background ” icon appears on the control panel display.

3)When in SLEEP mode, the fan will run on low to keep fan noise at a minimum.

4)When in Air Conditioner mode, the temperature setting will gradually increase to 2°F above the original set temperature for 6 hours. After 6 hours the temperature setting will return to the set temperature.

5)When in Heating mode, the temperature setting will gradually decrease to 2°F below the original set tem- perature for 6 hours. After 6 hours, the temperature setting will return to the set temperature.

6)When in Dehumidifier mode, the temperature will not change when Sleep mode is selected.

Compressor Indicator

The “ Manual background ” icon will light up on the control panel display when the compressor turns on. The “ Manual background ” icon will turn off when the compressor shuts off.

13

Page 13
Image 13
Soleus Air LX-140 manual Auto Mode, Compressor Indicator