ELECTRICAL REQUIREMENTS

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove the ground prong. Do not use an adapter

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock

Recommended Ground Method

The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front).

Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord.

Wiring Requirements

Power Supply Cord

 

 

115 volt (103.5 min.—126.5 max)

0-12 amps

15-amp time-delay fuse or circuit breaker

Use on single outlet circuit only

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus- tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.

It is the customer’s responsibility:

To contact a qualified electrician

To assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.

Copies of the standards listed may be obtained from: National Fire Protection Association

One Batterymarch Park

Quincy, Massachusetts 02269

LCDI Power Cord and Plug

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.

The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de- energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:

1.Plug power cord into a wall outlet

2.Press the TEST Button, the circuit should trip and cut all power to the air conditioner

3.Press the RESET button for use

If a test is performed and the indicator light remains ON, the current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Customer Service for troubleshooting recommendations.

3

Page 4
Image 4
Soleus Air SG-WAC-08ESE manual Electrical Requirements, Recommended Ground Method, It is the customer’s responsibility

SG-WAC-06SE, SG-WAC-08ESE, SG-WAC-06ESE specifications

Soleus Air has established itself as a prominent name in the air conditioning industry, consistently delivering effective solutions for both residential and commercial applications. Among their offerings, the SG-WAC-08ESE, SG-WAC-06ESE, and SG-WAC-06SE window air conditioners are notable for their impressive features, innovative technologies, and energy-efficient designs.

The Soleus Air SG-WAC-08ESE is designed for rooms up to 350 square feet, making it suitable for bedrooms, living rooms, and small offices. It boasts a cooling capacity of 8,000 BTUs, ensuring rapid temperature reductions even in hot summer months. One of its key features is the Energy Saver mode, which efficiently utilizes power by allowing the unit to automatically turn off once the desired temperature is achieved. This functionality not only saves on energy costs but also extends the lifespan of the unit.

Similarly, the SG-WAC-06ESE and SG-WAC-06SE models are aimed at slightly smaller spaces, covering areas of up to 250 square feet. With cooling capacities of 6,000 BTUs, these units are ideal for bedrooms or small living areas. The SG-WAC-06ESE includes an environmentally-friendly R-410A refrigerant, which contributes to lower greenhouse gas emissions. Additionally, both models feature a dehumidification function, effectively reducing humidity levels in the room and improving indoor air quality.

All three units are equipped with multiple cooling and fan speeds, allowing users to customize their comfort level according to specific needs. The straightforward digital controls, combined with a remote control feature, enhance user convenience by enabling adjustments from across the room. The washable and reusable air filter promotes cleaner air circulation and can be easily maintained.

In terms of installation, the Soleus Air models come with comprehensive instructions and all necessary hardware, simplifying the setup process for users. The sleek and modern design ensures that the units blend seamlessly with a variety of interior decors.

Overall, the Soleus Air SG-WAC-08ESE, SG-WAC-06ESE, and SG-WAC-06SE window air conditioners exemplify quality, efficiency, and user-friendly features, making them excellent choices for cooling spaces effectively and sustainably. With an emphasis on energy savings and ease of use, these models stand out in a competitive market, providing reliable climate control for a comfortable indoor environment.