Solid State Logic 82S6XR0A0B owner manual A.2.3 HF/LF Section G, A.2.4 OUTPUT Section H, Page A-2

Models: 82S6XR0A0B

1 8
Download 8 pages 16.96 Kb
Page 4
Image 4
X-Rack Owner’s Manual

X-Rack Owner’s Manual

A.2.3 HF/LF Section G

This section contains simple high and low pass filters as follows:

HF (Low Pass):

Frequency range 50kHz – 3kHz (–3dB point)

 

Slope: 12dB/Octave

LF (High Pass):

Frequency range 30Hz – 600Hz (–3dB point)

 

Slope: 18dB/Octave

The two filters can be switched into circuit independently.

A.2.4 OUTPUT Section H

This small section contains a tri-colour signal present indicator and two routing switches (‘REC L’ and ‘REC R’) which route the module signal onto a common internal record bus.

The signal present indicator measures signals immediately prior to the output amplifier. It will light GREEN for output signals above the lower threshold of –60dBu, AMBER for signals between +4dBu and +24dBu and lights RED for signals above +24dBu.

The record bus is not currently used but may be used by forthcoming X-Rack modules (such as the XR622 Mix/Monitor Module, due late 2006).

XR621

MIC

INST

IMP

INA.2.3 HF/LF Section GA.2.4 OUTPUT Section H LO Z HI

+48V

PAD

+12 dB +75

LINE

LINE

-20 dB +20

ØPage A-2

HF

9

6

 

30

4

 

IN

 

G

50

KHz 3

 

 

LF

160

300

 

60

 

 

IN

 

 

30

600

 

REC

OUTPUT

 

 

L

 

 

 

SIGNAL

REC

 

H

R

 

INSTRUMENT

 

 

GND

 

 

LIFT

 

 

Page A-2

Page 4
Image 4
Solid State Logic 82S6XR0A0B owner manual A.2.3 HF/LF Section G, A.2.4 OUTPUT Section H, Page A-2