![4. Synchronization Pro Tools® HD card](/images/new-backgrounds/16685/1668527x1.webp)
4. Synchronization Pro Tools® HD card
The Pro Tools® HD card is designed to operate as a Clock Slave, locking to a clock reference signal provided by the audio unit connected to its prim ary port. The interface unit can define the sa mple rate internally, or can itself be sy nchronized to an external reference signal (e.g. WordClock).
Whenever the user selects a sample rate setting in the PC or Macsoftware, the corresponding command is sent to the interface unit.
Delta-Link MADI HD
The
Although a reference signal is embedded in the Primary port, the MADI connection requires a separ ate WordClock signal. Therefore, the
Depending on the type of unit that is connected to the MADI port, the sample rate will no longer change automatically when a setting is selected in the PC or Mac software (because there is no command channel). Therefore, the sample rate must be set manually at both ends (in the Pro Tools® software and on the hardware connected to the MADI port).
10