Click Reset to Factory Defaults to initiate the process to reset the Helix to its default settings. After clicking on the button, the Helix will reset and you can connect to ACEmanager with the default username and password.

Debug

Debug mode allows direct control over the cellular module for additional control, technical support, and custom settings. Enabling this mode will disable the onboard cellular module control.

Figure 11-3: ACEmanager: Admin - Debug

Command

Description

 

 

Debug Enabled

Disabled or Enabled. Disabled is the default state. Enabling this option will pass control of

 

the cellular module to an external device for control.

 

"0">Disabled;"1">Enabled

 

 

Debug Output

TCP or DB9. This option selects the output of the debug control. TCP will send the output

 

over TCP and DB9 will send the output over the serial port.

 

"0">TCP;"1">DB9

 

 

BAUD Rate

Speed of the port.

 

 

TCP Port

The port to connect to, is specified when using the TCP debug mode.

 

 

Here is how to configure the Helix for debug mode using AT commands:

1.Set Debug Enabled option to Enabled.

2.Set Debug Output to DB9 for output to the DB9 on the device. The TCP option can be used if a virtual serial port is setup on the host device.

3.Set Dev Port to the radio module port that pass through mode to AT.

4.Set the BAUD Rate to 115200

5.Set the TCP Port if Debug Output is set to TCP. Ignore this option if you are using a serial cable

6.Click the Apply button and OK in the popup window that reads: “Applied the changes successfully.”

7.Click Reboot button.

8.Attach a serial cable to the Helix device after it has been rebooted.

Note: The Helix must be rebooted when enabling or disabling debug mode.