122GB
D:\NORM'S JOB\SONY HA\SO0054\STR-DA2400ES\CEL VERSION\3289204423\04GB-
STRDA2400ESUC\110ADD_GB.fm
masterpage: Left
STR-DA2400ES
3-289-204-42(3)

Specifications

Amplifier section

Power Output
Models of area code CEL, CEK, ECE, TW
Rated Power Output at Stereo Mode1)
(8 ohms 20 Hz – 20 kHz, THD 0.09%):
100 W + 100 W
Reference Power Output at Stereo Mode
(4 ohms 20 Hz – 20 kHz, THD 0.15%):
85 W + 85 W
Reference Power Output (8 ohms 1 kHz, THD
0.7%)
FRONT2): 110 W + 110 W
CENTER2): 110 W
SURROUND2): 110 W + 110 W
SUR BACK2): 110 W + 110 W
Reference Power Output (4 ohms 1 kHz, THD
0.7%)
FRONT2): 100 W + 100 W
CENTER2): 100 W
SURROUND2): 100 W + 100 W
SUR BACK2): 100 W + 100 W
1)Measured under the following conditions:
2)Depending on the sound field settings and the
source, there may be no sound output.
Frequency response
PHONO RIAA equalization curve
± 0.5 dB
Analog 10 Hz – 100 kHz,
± 3 dB (with sound field
and equalizer bypassed)
Input
PHONO Sensitivity: 2.5 mV
Impedance: 50 kohms
S/N3): 90 dB (A, 20 kHz
LPF)4)
Analog Sensitivity: 150 mV/
50 kohms
S/N3): 100 dB (A, 20 kHz
LPF)4)
Digital (Coaxial) Impedance: 75 ohms
S/N3): 96 dB
(A, 20 kHz LPF)4)
Digital (Optical) S/N3): 96 dB
(A, 20 kHz LPF)4)
Output (analog)
AUDIO OUT Voltage: 150 mV/
1 kohm
SUB WOOFER Voltage: 2 V/1 kohm
Equalizer
Gain levels ±10 dB, 1 dB step
3)INPUT SHORT (with sound field and equalizer
bypassed).
4)Weighted network, input level.

FM tuner section

Tuning range 87.5 – 108.0 MHz
Antenna (aerial) FM wire antenna (aerial)
Antenna (aerial) terminals
75 ohms, unbalanced
Intermediate frequency
10.7 MHz

AM tuner section

Tuning range
5)You can change the AM tuning scale to either 9
kHz or 10 kHz. After tuning in any AM station,
turn off the receiver. While holding down
TUNING MODE, press POWER on the receiver.
All preset stations will be erased when you change
the tuning scale. To reset the scale to 10 kHz (or 9
kHz), repeat the procedure.
Antenna (aerial) Loop antenna (aerial)
Intermediate frequency
450 kHz
Area code Power requirements
CEL, CEK, ECE 230 V AC, 50 Hz
TW 110 V AC, 60 Hz
Area code Tuning scale
10 kHz step 9 kHz step
CEL, CEK, ECE 531 kHz
1,602 kHz
TW 530 kHz
1,610 kHz5) 531 kHz
1,602 kHz5)