How to Use the Camera

EXPOSURE

MAIN SETUP

1.LENS DC 2.EXPOSURE

3.WHITE BAL ATW

4.BACKLIGHT OFF

5.SSNR ON

6.DAY/NIGHT AUTO 7.IMAGE ADJ 8.SPECIAL

9.EXIT

1. When the SETUP menu screen is displayed, select EXPOSURE by using the Up and Down buttons so that the arrow indicates EXPOSURE .

2. Select a desired mode using the Up and Down buttons.

SHUTTER : You can select either auto or manual shutter.

-A.FLK : Select this when you experience picture flicker, which can happen when there is a clash with the frequency of the installed lighting.

-ESC : Select this to control the shutter speed automatically. If ESC is selected, the shutter speed is automatically controlled depending on the ambient illumination of the subject.

-MANUAL : You can control shutter speed manually.

Notes

¥When the SHUTTER is set to ESC after selecting the Internal Synchronization Type, the picture may become unstable if the camera faces a bright fluorescent light. Therefore, take care when choosing the installation position.

¥ESC and MANUAL modes are only available together when the lens is set to

MANUAL.

¥When the SHUTTER is set to MANUAL or A.FLK mode, SENS-UP will be disabled.

AGC (AUTO GAIN CONTROL):

The higher the gain level, the brighter the screen - but the higher the noise.

-OFF : Deactivates the AGC function.

-LOW : Allows automatic gain control from 0 to 30dB.

-HIGH : Allows automatic gain control from 0 to 42dB.

SENS-UP :

When it is night or dark, the camera automatically detects the light level and maintains a clear picture if this mode is activated.

- OFF : Deactivates the SENS-UP function.

- AUTO : Activates the SENS-UP function.

RETURN :

Select this to save the changes in the EXPOSURE menu and return to the SETUP menu.

Notes

¥If you press the SET button in ÔAUTOÕ mode, You can adjust brightness by increasing or decreasing the shutter speed. (X2~X256)

¥Note that the higher the zoom level, the brighter the screen, but the more likely it is that an after-image will appear.

¥Although Noise, Spots, and Whitish symptoms may occur in SENS-UP operation when the zoom level is increased, this is normal.

COLOR CCD CAMERA 26 User’s Manual

COLOR CCD CAMERA 27 User’s Manual