Temperature and Humidity Range

Temperature

Operating

5 ˚C to 40 ˚C (T<10 ˚C/h)

 

 

Non-Operating (mech.)

– 40 ˚C to 70 ˚C (T<20 ˚C/h)

 

 

Non-Operating (tape)

– 40 ˚C to 45 ˚C (T<20 ˚C/h)

Humidity

 

 

 

Operating

20 to 80% RH, non-condensing

 

Maximum wet bulb temperature = 26 ˚C

 

 

Non-Operating (mech.)

5 to 95% RH (T<30%/h)

 

 

Non-Operating (tape)

20 to 80% RH (T<30%/h)

 

 

Power Requirements

Voltage

Max Ripple

 

Current

 

 

 

Typical

 

Maximum

 

 

 

5 V +/– 5 %

100 mVp-p

2.5 A

 

2.9 A

 

 

 

 

 

12 V +/– 10 %

150 mVp-p

0.4 A

 

2.0 A

 

 

 

 

 

Suspended Particulate

Operating

Less than 150 microgram/m3

Based Sampling period 24 hours

 

 

 

ESD

 

Discharge

< 8 kV: No operation failure

Voltage

 

 

 

Air-cooling Requirement

Surrounding temperature

< 40 ˚C

Clean air flow is recommended to minimize the possibility of data loss.

20

Page 20
Image 20
Sony AITi260 manual Temperature and Humidity Range, Power Requirements, Suspended Particulate, Air-cooling Requirement