Temperature and Humidity Range
Temperature
Operating | 5 ˚C to 40 ˚C (∆ T<10 ˚C/h) |
|
|
– 40 ˚C to 70 ˚C (∆ T<20 ˚C/h) | |
|
|
– 40 ˚C to 45 ˚C (∆ T<20 ˚C/h) | |
Humidity |
|
|
|
Operating | 20 to 80% RH, |
| Maximum wet bulb temperature = 26 ˚C |
|
|
5 to 95% RH (∆ T<30%/h) | |
|
|
20 to 80% RH (∆ T<30%/h) | |
|
|
Power Requirements
Voltage | Max Ripple |
| Current | |
|
|
| ||
Typical |
| Maximum | ||
|
|
| ||
5 V +/– 5 % | 100 | 2.5 A |
| 2.9 A |
|
|
|
|
|
12 V +/– 10 % | 150 | 0.4 A |
| 2.0 A |
|
|
|
|
|
Suspended Particulate
Operating | Less than 150 microgram/m3 | |
Based Sampling period 24 hours | ||
| ||
|
| |
ESD |
|
Discharge | < 8 kV: No operation failure |
Voltage |
|
|
|
Air-cooling Requirement
Surrounding temperature
< 40 ˚C
Clean air flow is recommended to minimize the possibility of data loss.