Troubleshooting and Maintenance 6 Chapter
Troubleshooting
If an alarm message appears on the monitor screen, or if the unit appears to be malfunctioning, please check the following before contacting your Sony dealer.
Tape problems
Symptom | Cause | Remedy | |
|
|
| |
Recording is not | The cassette’s REC/SAVE switch is set | Set the REC/SAVE switch to REC, or use another cassette. | |
possible. | to SAVE. a) |
| |
The unit’s tape | The REMOTE button is lit and the | Press the REMOTE button to turn it off, or change the setting | |
transport control | LOCAL ENABLE menu item is set to | of the LOCAL ENABLE menu item (see page 63) to ALL | |
buttons (PLAY, F FWD, | STOP & EJECT or ALL DISABLE. a) | ENABLE. | |
REW, etc.) do not |
|
| |
No cassette is loaded. a) | Insert a cassette (see page 29). | ||
work. | |||
The NOT EDITABLE | The audio recording mode selected on | • When your current purpose is editing, press the REMOTE | |
indicator on the front | this unit does not coincides with that of | button to turn it off and set the unit for the same audio | |
panel lights up. | the loaded tape. a) | recording mode as with the tape using the REC. MODE | |
|
| menu item (see page 69), then turn on the REMOTE | |
|
| button again. | |
|
| • When your current purpose is recording, you can use the | |
|
| tape currently loaded in the unit. | |
|
|
| |
| The recording format of the currently | Replace the tape with one recorded in the DVCAM format. | |
| loaded tape is “DV” or “DVCPRO.” a) |
|
a)In these states, an alarm message appears on the monitor screen and in the time counter display.
Time data problems
Symptom | Cause | Remedy |
|
|
|
Cannot freely set the | The TC MODE menu item is set to EXT | Change the setting of the TC MODE menu item (see page |
initial time data value. | REGEN. a) | 66) to INT PRESET. |
| CNT is selected as the time data type | Press the COUNTER SEL button to make the TC or |
| to be displayed (the COUNTER time | time data type indicator light up (the CNT value cannot be |
| data type indicator is lit). a) | set freely). |
| The REMOTE button is lit and the | Press the REMOTE button to turn it off or change the setting |
| LOCAL ENABLE menu item is set to | of the LOCAL ENABLE menu item (see page 63) to ALL |
| STOP & EJECT or ALL DISABLE. a) | ENABLE. |
The tape is running, | The MENU button or TC PRESET | Press the button once again to exit the menu control mode, |
but the time data is not | button on the menu control panel has | time code preset mode, or digital hours meter display mode. |
shown in the time | been pressed. | (In either of the menu control mode and time code preset |
counter display. |
| mode, the time data is not shown in the time counter display.) |
|
|
|
| The | Press the COUNTER SEL button to make the COUNTER or |
|
| TC time data type indicator light up. |
|
|
|
a)In these states, an alarm message appears on the monitor screen and in the time counter display.
Input problem
Symptom | Cause | Remedy |
|
|
|
It is not possible to | No SDTI signal is input to the unit. a) | Connect an SDTI signal to the SDTI (QSDI) IN connector. |
record an SDTI (QSDI) |
|
|
signal. |
|
|
|
|
|
a)In this state, an alarm message appears on the monitor screen and in the time counter display.