Operation Warnings
When a problem occurs at power on or during operation, a warning is given by one of the following.
•Warning indicators on the STATUS screen of the LCD monitor
•WARNING lamps, and audible warnings from the speaker and earphones
•Indicators on the viewfinder
The volume of the audible warnings can be adjusted with the ALARM knob. Set the ALARM knob to the minimum to mute the sound.
STATUS screen of |
| Warning | Indicators in |
|
|
| |
the LCD monitor | WARNING lamp | sounds | viewfinder |
|
|
| |
and viewfinder |
|
|
|
| Problem | VTR operation | Action to take |
|
| Continuous | REC/ | BATT | |||
|
|
|
|
| |||
Warning indicator | :Continuous | 1 beep/s | TALLY |
|
|
|
|
:1 flash/s | :Continuous |
|
|
| |||
|
|
|
|
| |||
| :4 flashes/s | 4 beeps/s | :1 flash/s |
|
|
| |
|
|
| :4 flashes/s |
|
|
| |
Warning: RF | 1) | 1) | 1) |
| Clogging of | A warning sound | Clean the video |
|
|
|
|
| the video | is heard when | head. If recording |
|
|
|
|
| head. Trouble | clogging of the | still fails after |
|
|
|
|
| in the | head is | cleaning the head, |
|
|
|
|
| recording | detected. | turn off the power |
|
|
|
|
| section. | Recording may | and consult your |
|
|
|
|
|
| fail. | Sony |
|
|
|
|
|
|
| representative. |
Warning: SERVO | 2) | 2) | 2) |
| Servo | Recording | Turn off the power |
|
|
|
|
| problems. | continues but | and consult your |
|
|
|
|
|
| may be | Sony |
|
|
|
|
|
| substandard. | representative. |
Warning: HUMID |
|
|
|
| Condensation | During | While the power is |
|
|
|
|
| occurs. | recording, | turned on, wait |
|
|
|
|
|
| recording | until the HUMID |
|
|
|
|
|
| continues. | indicator |
|
|
|
|
|
| Otherwise, | disappears. |
|
|
|
|
|
| operation stops. |
|
|
|
|
|
|
| Ejecting the tape |
|
|
|
|
|
|
| is the only |
|
|
|
|
|
|
| operation |
|
|
|
|
|
|
| allowed. |
|
Warning: SLACK |
|
|
|
| Trouble when | Operation stops. | Follow the |
Er |
|
|
|
| forwarding or |
| instructions given |
|
|
|
|
| rewinding a |
| in the error code |
|
|
|
|
| tape. |
| list (page 127). |
|
|
|
|
|
|
| Turn off the power |
|
|
|
|
|
|
| and consult your |
|
|
|
|
|
|
| Sony |
|
|
|
|
|
|
| representative.3) |
Warning: |
|
|
|
| Trouble when | Operation stops. | Follow the |
CASSETTE |
|
|
|
| inserting or |
| instructions given |
Er |
|
|
|
| ejecting a |
| in the error code |
|
|
|
|
| cassette. |
| list (page 127). |
|
|
|
|
|
|
| Turn off the power |
|
|
|
|
|
|
| and consult your |
|
|
|
|
|
|
| Sony |
|
|
|
|
|
|
| representative. |
Appendix 7 Chapter
Operation Warnings 125