Chapter 8 Connections and Settings
120 Chapter 8 Connections and Settings
Connections for Parallel Recording Using TwoUnits

The following shows connections for parallel

recording using two DSR-70/70P units.

In the following, the controlling unit is referred to as
the recorder and the controlled unit as the player.

For information about how to carry out two-unit parallel

recording, see the section “Parallel Recording Using Two

Units” on page 81.

The connections and settings to be made differ

depending on the timecode to be used, as follows.

Inputting an external timecode to both the player and recorder

AUDIO
INPUT
CH-1
TC IN
VIDEO
INPUT VIDEO
INPUT
REMOTEREMOTE
TC IN
TC OUT
AUDIO
INPUT
CH-1
Player settings
Switch/menu Setting
VIDEO INPUT 75 termination
switch
REMOTE/LOCAL switch REMOTE
ON
Recorder settings
Switch/menu Setting
VIDEO INPUT 75 termination
switch
REMOTE/LOCAL switch LOCAL
ON
TC INT/EXT switch EXT
Sub LCD menu item
PRESET/REGEN REGEN
TC INT/EXT switch EXT
Sub LCD menu item
PRESET/REGEN REGEN
Setup menu item 201 ENA Setup menu item 201 ENA
Audio signal
Video signal
DSR-70/70P (player) DSR-70/70P (recorder)
1
2
Audio signal
Video signal
1
2Timecode
2
2
3
1 XLR cable (not supplied)
Setup menu item 611 THRU
2 75 coaxial cable (not supplied)
3 RCC-5G/10G/30G 9-pin remote control cable
(length 5 m (16 ft)/10 m (33 ft)/30 m (98 ft), not
supplied)