Chapter 9 Maintenance and Troubleshooting
Chapter 9 Maintenance and Troubleshooting 131
Error Messages
This unit is provided with a self-diagnostic function
that detects internal abnormalities. When it detects an
abnormality, it outputs an error message to the monitor
screen and indicates an error code in the sub LCD.
Note
To display error messages on the monitor screen, set
the CHARACTER switch to ON.
Alarm Messages

Error02-603

ERROR
AN ERROR HAS BEEN
DETECTED. INFORM SERVICE
OF FOLLOWING CODE:
02-603
PRESS EJECT KEY
TO EJECT TAPE.
Error code
Error message
Error code
Direction
Monitor screen Sub LCD
When a setting, connection or operation error has been
made, or when a problem such as condensation on
heads has occurred, the unit outputs alarm messages
such as the ones shown below to the monitor screen
and the sub LCD.

REMOTE!

ALARM
REMOTE MODE IS SELECTED
SET REMOTE/LOCAL SWITCH
TO LOCAL
Cause of alarm
Direction
Monitor screen Sub LCD
If an alarm message appears, follow the direction
indicated under the message on the monitor screen. To display alarm messages on the monitor screen, set
the CHARACTER switch to ON, and setup menu item
016 (ALARM) and 106 (REFERENCE SYSTEM
ALARM) to ON or LIMIT.