TRIGGER

Set when you use a slave unit connected to the TRIG IN connector and synchronize the camera with a stroboscope.

Selection

Function

 

 

 

 

 

OFF

Select when you do not connect a slave unit.

 

 

 

 

 

ON

Select when you connect a slave unit.

 

Select POLARITY, and set it to the same polarity as

 

the input pulse signal.

 

 

 

 

: Falling edge

 

 

 

 

 

 

: Rising edge

 

 

 

 

 

 

 

 

NEGA

Reverses the output image to negative/positive.

Selection

Function

 

 

OFF

Outputs the image normally.

 

 

ON

Outputs the image reversed to negative/positive.

 

 

FLICKER CANCELLER

When using the camera in a 50 Hz lighting area (DXC-390) or in a 60 Hz lighting area (DXC-390P), you can obtain images with less flicker under fluorescent light even when SHUTTER is set to CCD IRIS or OFF. Set this item to OFF when you want to set NEGA to ON.

Selection

Function

 

 

OFF

Disables the FLICKER CANCELLER function.

 

 

ON

Reduces flicker.

 

 

SYSTEM menu

Sets the items relating to the system of the camera and selection of output signals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<SYSTEM>

 

 

[A]

 

 

 

 

 

>BAUD RATE

 

 

9600

 

 

 

 

 

 

D-SUB VIDEO

VBS

 

 

 

 

 

 

D-SUB SYNC

C.SYNC

 

 

 

 

 

 

RGB SYNC

 

 

G

 

 

 

 

 

 

12P CONNECTOR

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

Select

 

Back

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting items in the SYSTEM menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting item

Contents of setting

 

 

Ref. page

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAUD RATE

Selects the baud rate.

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-SUB VIDEO

Switches the video signal output from

28

 

the

 

 

 

 

 

 

RGB/SYNC connector (D-

 

 

sub 9-pin).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-SUB SYNC

Switches the sync signal output from

28

 

the

 

 

 

 

 

 

RGB/SYNC connector (D-

 

 

sub 9-pin).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGB SYNC

Adds a sync signal to the RGB output.

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12P

Switches the input and output of the

29

CONNECTOR

 

 

 

 

 

DC IN/VBS

 

connector and

 

 

 

 

 

 

 

selects the output signal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Continued)

2 Chapter