Pin No.

Pin Name

I/O

Function

61

LOAD IN

O

Tray loading motor control signal, “L”:Loading

 

 

 

 

62

LOAD OUT

O

Tray loading motor control signal, “L”:When OPEN

 

 

 

 

63

BD.RESET

O

IC reset signal for CD control, “L”:RESET

 

 

 

 

64

LIGHT

O

BLUE LED control port of front panel, “L”:LED ON

 

 

 

 

65

SDATA

O

Serial data for SOUND PROCESSOR IC101 (M62428AFP)

 

 

 

 

66

SCLOCK

O

Serial clock for SOUND PROCESSOR IC101 (M62428AFP)

 

 

 

 

67

SLAT1

O

Chip select for SOUND PROCESSOR IC101 (M62428AFP)

 

 

 

 

68

MUTE1

O

Audio mute signal, “H”:Power amplifier ICs (IC801, IC851) MUTE

 

 

 

 

69

MUTE2

O

Audio mute signal, “L”:Line mute (Q141, Q241) MUTE

 

 

 

 

70

STANDBY LED

O

Signal controlling LED which lights when power is OFF, “L”:LED ON

 

 

 

 

71

VSS0

Ground potential of port

 

 

 

 

72

ON LED

O

Signal controlling LED which lights when power is ON, “L”:LED ON

 

 

 

 

73

TIMER LED

O

Signal controlling LED which lights in timer standby, “H”:LED ON

 

 

 

 

74

I

Not used

 

 

 

 

75

FL DISP SW

O

Power ON/OFF signal for FL display, “H”:FL display ON

 

 

 

 

76

SP RELAY SW

O

Speaker relay control signal, “L”:Speaker relay ON

 

 

 

 

77 to 80

I

Not used

 

 

 

 

81

ON/XSTBY

O

System power control signal, “H”:Standby relay ON

 

 

 

 

82

STEREO

I

Tuner stereo signal, “L”:Stereo

 

 

 

 

83

TUNED

I

Tuner selection OK signal, “L”:TUNED

 

 

 

 

84

ST IDATA

I

Serial input data for tuner

 

 

 

 

85

ST ODATA

O

Serial output data for tuner

 

 

 

 

86

ST.CLOCK

O

Serial clock for tuner

 

 

 

 

87

ST LATCH

O

Chip select for tuner

 

 

 

 

88

ST MUTE

O

Tuner mute output

 

 

 

 

89

ST POWER

O

Tuner power signal (Not used)

 

 

 

 

90

SIRCS

I

SIRCS code input signal (Remote control signal input)

 

 

 

 

91

PCL

I

32 KHz clock monitor out

 

 

 

32.768 kHz signal is output in the test mode (Refer to page 12.)

 

 

 

 

92, 93

I

Not used

 

 

 

 

94

DEST1

I

Destination differentiation signal (Fixed at “H”)

 

 

 

 

95

DEST2

I

Destination differentiation signal (Fixed at “L”)

 

 

 

 

96

I

Not used

 

 

 

 

97

HP MUTE

O

HP mute signal output

 

 

 

 

98

MD-MUTE

O

MD REC OUT control signal “L”:MD REC OUT MUTE (“L” only for MD function)

 

 

 

 

99

TC-MUTE

O

REC OUT control signal of TAPE

 

 

 

“L”:TAPE REC OUT MUTE (“L” only for TAPE function)

 

 

 

 

100

V/T

O

Function control signal “H”:TAPE, “L”:CS/BS

 

 

 

 

– 55 –

Page 37