Step 2: Attaching the supplied items (Continued)

MANUAL SERVO

ZOOM

Adjusting the flange focal length automatically

1Set the ND filter B to 1 to adjust brightness so that the proper video light level is obtained.

2Place the flange focal length adjustment test chart A about 2-3 meters (7-10 feet) away. Zoom in and set your camcorder to locate the center of the chart in the center of the screen.

3Set the ZOOM switch F to SERVO.4Select [AUTO ADJUST] in [FLANGEBACK] of the (CAMERA SET) menu (p. 73).5Select [YES] with the SEL/PUSH EXEC dial E.

The flange focal length adjustment starts and [EXECUTING] appears on the screen. When the adjustment is completed, [Completed..] appears on the screen.

If the adjustment fails, [Could not adjust.] appears on the screen. Try the adjustment again.

Adjusting the flange focal length manually1Perform steps 1 and 2 of “Adjusting the flange focal length automatically.”2Set the ZOOM switch F to MANUAL.
3Select [MANU ADJUST] in [FLANGEBACK] of the (CAMERA SET) menu.4Select [YES] with the SEL/PUSH EXEC dial E.5Turn the zoom ring D to the telephoto position.6Turn the focus ring C until the subjectcomes in focus, then press the SEL/ PUSH EXEC dial E.7Turn the zoom ring D to the wide angle position.8Turn the focus ring C until the subject

comes in focus, then press the SEL/ PUSH EXEC dial E.

When the adjustment is completed, [Completed.] appears on the screen.

If the adjustment fails, [Could not adjust.] appears on the screen. Try the adjustment again.

zTips

You can check the focusing easily if you do the following before adjusting the focal length.

Set the PEAKING switch to ON (p. 31).

Press the ASSIGN button to which [EXP.FOCUS] is assigned (p. 48).