SELF-DIAGNOSIS FUNCTION
The
Procedure for using the
Note:
Perform the
1. | While pressing the | INPUT | button and p button, connect the power plug to the outlet, and release the | INPUT | button and p button. | ||||
2. | Press the |
| button and when “[Service]” is displayed, press the |
| button. | ||||
+ | ^ “PROGRAM” |
3.Press the + button and display “ERR DP MODE”.
4.Pressing the ^“PROGRAM” button sets the error history mode and displays “total rec”.
5.Select the contents to be displayed or executed using the + button.
6.Pressing the r“PROGRAM” button will display or execute the contents selected.
7.Pressing the r“PROGRAM” button another time returns to step 4.
8.Pressing the p“PROGRAM” button displays “ERROR DP MODE” and exits the error history mode.
9.To exit the test mode, press the 6“1” button. The unit sets into the STANDBY state, the disc is ejected, and the test mode ends.
*Note:
As this unit has only a few buttons, one button is assigned with several functions in the test mode.
Press the INPUT button to switch the functions.
Each time the INPUT button is pressed, the display switches in the following order; “PROGRAM” n“1” nblank n“PROGRAM” The functions of each button change with the display.
For simplicity, operations of the INPUT button will not be described here.
Instead, symbols are added to the names of buttons. Press the INPUT button as required to switch the display.