Sony MDX-C5970 Avrh, Avrl, KEY-IN1, KEY-IN2, RC-IN0, Bass, Quality, Meter, Vsm, Ill, Acc, Af-Seek

Models: MDX-C5970 MDX-C5970R

1 66
Download 66 pages 43.45 Kb
Page 49
Image 49

Pin No.

Pin Name

I/O

 

 

Function

 

 

 

 

 

 

 

 

43

AVRH

I

Reference voltage (+5V) input terminal (for A/D converter)

 

 

 

 

 

 

 

 

44

AVRL

I

Reference voltage (0V) input terminal (for A/D converter)

 

 

 

 

 

 

 

 

 

 

45

 

AVSS

Ground terminal (for A/D converter)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Key input terminal (A/D input) (LSW801 to LSW804, LSW806 to LSW810)

 

46

KEY-IN0

I

OFF, SOURCE, SEEK/AMS + )+ = 0 – , DSPL, SOUND, MODE, SHIFT, 1, 2

 

 

 

 

 

keys input (LSW804 DSPL: MDX-C5960R/C5970R only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Key input terminal (A/D input) (LSW811 to LSW821)

 

47

KEY-IN1

I

6, AF/TA (MDX-C5960R/C5970R) DSPL (MDX-C5970), LIST PTY (MDX-C5960R/

 

 

 

 

 

C5970R) LIST (MDX-C5970), 10 to 3 keys input

 

 

 

 

 

 

 

 

 

 

 

48

KEY-IN2

I

Key input terminal (A/D input)

Not used (open)

 

 

 

 

 

 

 

 

 

49

RC-IN0

I

Rotary remote commander key input terminal (A/D input)

 

 

 

 

 

 

 

 

50

D-BASS IN

I

D-BASS switch (LSW805) input terminal (A/D input)

 

 

 

 

 

 

 

 

51

QUALITY

I

Noise level detection signal input at SEEK mode (A/D input)

 

Used for the MDX-C5960R/C5970R only (MDX-C5970: Not used (open))

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52

MPDH (MTP)

I

Multi-path detection signal input from the RDS decoder (IC102) (A/D input)

 

Used for the MDX-C5960R/C5970R only (MDX-C5970: Not used (open))

 

 

 

 

 

 

 

 

 

 

 

 

 

53

S-METER

I

FM and AM signal meter voltage detection input from the FM/AM tuner unit (TU1)

(VSM)

(A/D input)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54

 

VCC

Power supply terminal (+5V)

 

 

 

 

 

 

 

 

 

 

55

AMP ATT

O

Power amp muting on/off control signal output to the power amplifier (IC500)

“L”: muting on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

56

AMP ON

O

Standby on/off control signal output to the power amplifier (IC500)

 

“L”: standby mode, “H”: amp on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

ILL IN

I

Auto dimmer control illumination line detection signal input terminal

 

“L” is input at dimmer detection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

LOCK IN

I

Mini-disc lock detection signal input from the MD mechanism controller (IC501) “H”: lock

59

EMPH ON

O

Emphasis control signal output terminal Not used (open)

 

 

 

 

 

 

60

AU ATT

O

Audio line muting on/off control signal output terminal “H”: muting on

 

 

 

 

 

 

61

AF ATT

O

Preamp muting on/off control signal output to the electrical volume (IC300)

“H”: muting on

 

 

 

 

 

 

 

62

TU-ATT

O

Muting on/off control signal output of the FM tuner signal “H”: muting on

 

Used for the MDX-C5960R/C5970R only (MDX-C5970: Not used (open))

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

 

VSS

Ground terminal

 

 

 

 

64

ACC IN

I

Accessory detect signal input terminal

“L”: accessory on

 

 

 

 

 

 

 

 

65

AF-SEEK

O

PLL low-pass filter time constant selection signal output at AF SEEK

 

“H” is output when AF SEEK

Not used (open)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF band select signal output terminal

“H”: wide mode

 

66

 

WIDE

O

In receiving FM signals, interference noise from adjacent stations is removed by narrowing the

 

IF band automatically in the tuner unit so as to raise the selectivity, but in this case, the distortion

 

 

 

 

 

 

 

 

 

 

may increase and accordingly, the IF band is widened forcibly Not used (open)

 

 

 

 

 

 

 

67

DAVN

I

Data transmit completed detect signal input from the RDS decoder (IC102)

“H” active

Used for the MDX-C5960R/C5970R only (MDX-C5970: Not used (open))

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

NARROW

O

Narrow select signal output terminal

“H” active

Not used (open)

 

 

 

 

 

 

69

SSTOP

I

IF counter request signal input from the FM/AM PLL (IC100)

 

 

 

 

 

 

 

70

 

SDA

I/O

Two-way data bus with the FM/AM PLL (IC100), RDS decoder (IC102) and electrical volume

 

(IC300) (RDS decoder is MDX-C5960R/C5970R only)

 

 

 

 

 

 

 

 

 

 

 

 

 

71

 

SCL

O

Bus clock signal output to the FM/AM PLL (IC100), RDS decoder (IC102) and electrical volume

 

(IC300) (RDS decoder is MDX-C5960R/C5970R only)

 

 

 

 

 

 

 

72

RC-IN1

I

Rotary remote commander shift key input terminal

“L”: shift

 

 

 

 

 

 

 

 

73

 

X1A

O

Sub system clock output terminal (32.768 kHz)

 

 

 

 

 

 

 

 

 

74

 

X0A

I

Sub system clock input terminal (32.768 kHz)

 

 

 

 

 

 

 

 

 

 

 

 

– 69 –

Page 49
Image 49
Sony MDX-C5970 Avrh, Avrl, KEY-IN1, KEY-IN2, RC-IN0, Bass, Quality, Meter, Vsm, Ill, Acc, Af-Seek, Wide, Davn, Narrow, Sda