20
MZ-N707
2. NV adjusted values modifying procedure
1) Select manual mode of the test mode, and set item number
336 (see page 14).
2) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
08.
3) Press the Xkey to write the adjusted value.
4) Select manual mode of the test mode, and set item number
741 (see page 14).
5) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
02.
6) Press the Xkey to write the adjusted value.
7) Select manual mode of the test mode, and set item number
771 (see page 14).
8) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
6E.
9) Press the Xkey to write the adjusted value.
10) Select manual mode of the test mode, and set item number
772 (see page 14).
11) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
7C.
12) Press the Xkey to write the adjusted value.
13) Select manual mode of the test mode, and set item number
773 (see page 14).

AbcdGn **

3 36

**
: Adjusted value
Set LCD display

BatFlg **

7 41

**
: Adjusted value
Set LCD display

NiRec0 **

7 71

**
: Adjusted value
Set LCD display

NiRec1 **

7 72

**
: Adjusted value
Set LCD display

NiRec2 **

7 73

**
: Adjusted value
Set LCD display
14) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
7D.
15) Press the Xkey to write the adjusted value.
16) Select manual mode of the test mode, and set item number
774 (see page 14).
17) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
7F.
18) Press the Xkey to write the adjusted value.
19) Select manual mode of the test mode, and set item number
775 (see page 14).
20) Adjust with the [VOL +] key (adjusted value up) or [VOL--]
key (adjusted value do wn) so that the adjusted value becomes
81.
21) Press the Xkey to write the adjusted value.
22) Select manual mode of the test mode, and set item number
776 (see page 14).
23) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
5B.
24) Press the Xkey to write the adjusted value.
25) Select manual mode of the test mode, and set item number
777 (see page 14).
26) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
7B.
27) Press the Xkey to write the adjusted value.

NiRec3 **

7 74

**
: Adjusted value
Set LCD display

NiRec4 **

7 75

**
: Adjusted value
Set LCD display

NiPb 0 **

7 76

**
: Adjusted value
Set LCD display

NiPb 1 **

7 77

**
: Adjusted value
Set LCD display