21
MZ-N707
41) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
B9.
42) Press the Xkey to write the adjusted value.
43) Select manual mode of the test mode, and set item number
867 (see page 14).
44) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
C9.
45) Press the Xkey to write the adjusted value.
46) Select manual mode of the test mode, and set item number
868 (see page 14).
47) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
80.
48) Press the Xkey to write the adjusted value.
49) Select manual mode of the test mode, and set item number
871 (see page 14).
50) Adjust with the [VOL +] key (adjusted value up) or [VOL--]
key (adjusted value do wn) so that the adjusted value becomes
CA.
51) Press the Xkey to write the adjusted value.
52) Select manual mode of the test mode, and set item number
872 (see page 14).
53) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
2D.
54) Press the Xkey to write the adjusted value.
28) Select manual mode of the test mode, and set item number
778 (see page 14).
29) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
7D.
30) Press the Xkey to write the adjusted value.
31) Select manual mode of the test mode, and set item number
779 (see page 14).
32) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
7F.
33) Press the Xkey to write the adjusted value.
34) Select manual mode of the test mode, and set item number
781 (see page 14).
35) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
81.
36) Press the Xkey to write the adjusted value.
37) Select manual mode of the test mode, and set item number
865 (see page 14).
38) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value do wn) so that the adjusted value becomes
2C.
39) Press the Xkey to write the adjusted value.
40) Select manual mode of the test mode, and set item number
866 (see page 14).

NiPb 2 **

7 78

**
: Adjusted value
Set LCD display

NiPb 3 **

7 79

**
: Adjusted value
Set LCD display

NiPb 4 **

7 81

**
: Adjusted value
Set LCD display

V3 dat **

8 66

**
: Adjusted value
Set LCD display

V4 num **

8 67

**
: Adjusted value
Set LCD display

V4 dat **

8 68

**
: Adjusted value
Set LCD display

V3 num **

8 65

**
: Adjusted value
Set LCD display

V5 num **

8 71

**
: Adjusted value
Set LCD display

V5 dat **

8 72

**
: Adjusted value
Set LCD display