![[General Adjustment Mode]](/images/new-backgrounds/26138/2613859x1.webp)
[General Adjustment Mode]
•Set the test mode, press the +key, and set the general adjust- ment mode.
•To set other modes, cut off the power once and power on again.
•When the general adjustment mode is set, the LCD display will be as follows.
4000
Assy MODE
• Structure of General Adjustment Mode
General
adjustment mode
Ókey (CD, MO discrimination)
CD automatic | Ó key |
adjustment | OK |
| |
| p key |
p key | NG |
|
MO automatic | Ó key |
adjustment | OK |
| |
| p key |
p key | NG |
|
• MO Automatic Adjustment
No. | Mode No. | Adjustment |
|
|
|
1 | 032 | MO playback EF balance adjustment |
|
|
|
2 | 033 | MO playback ABCD level adjustment |
|
|
|
3 | 034 | MO recording EF balance adjustment |
|
|
|
4 | 035 | MO recording ABCD level adjustment |
|
|
|
5 | 037 | MO focus gain adjustment |
|
|
|
6 | 038 | MO tracking gain adjustment |
|
|
|
7 | 061 | 32 cluster full REC |
|
|
|
8 | 062 | REC shock |
|
|
|
9 | 063 | 32 cluster PLAY |
|
|
|
10 | 039 | MO focus bias adjustment |
|
|
|
11 | 042 | Low reflection CD EF balance adjustment |
|
|
|
12 | 043 | Low reflection CD ABCD level adjustment |
|
|
|
13 | 045 | Laser low reflection CD read adjustment |
|
|
|
14 | 046 | Low reflection CD tracking gain adjustment |
|
|
|
* Display during MO automatic adjustment
37 | Mode No. |
| during adjustment |
MO RUN
4.If the automatic adjustment results are OK, the following will be displayed.
Reset
Adjusting Method :
1.Set the test mode, press the = key to set the general adjust- ment mode.
2.Load the CD test disc
3.When the Ókey is pressed, the disc is determined if CD or MO, the automatic adjustment modes are set, and adjustments are per- formed automatically in the following order.
• CD Automatic Adjustment
No. | Mode No. | Adjustment |
|
|
|
1 | 052 | CD EF balance adjustment |
|
|
|
2 | 053 | CD ABCD level adjustment |
|
|
|
3 | 055 | CD focus gain adjustment |
|
|
|
4 | 056 | CD tracking gain adjustment |
|
|
|
5 | 057 | CD focus bias adjustment |
|
|
|
* Display during CD automatic adjustment
51 Mode No.
during adjustment
CD RUN
00
CD mode OK
5.If the automatic adjustment results are NG, the following will be displayed.
NG mode No. (Last 2 digits)
557F Adjustment results
CD mode NG
*When the mode number is 039, 057 and the focus bias value is NG, the following will be displayed
Mode No. (Last 2 digits)
5730 Focus bias value
CD mode NG
77 : focus bias | Displayed while the P key is | |
pressed | ||
|
7701 Error code
(01 to 04)
CD mode NG
*When the mode number is 039, 061 and the AT error rate is NG, the following will be displayed.
Mode No. (Last 2 digits)
3903 AT error value
CD mode NG
*When NG, set the servo mode and perform the automatic adjust- ment of the NG item. (Refer to “Servo Mode”).