Adjustment Using the Menus 25
REMOTE menu
Submenu Setting
PARALLEL REMOTE Selects the PARALLEL REMOTE
connector pins for which you want
to change the function.
You can assign various functions to
1 to 4 pins and 6 to 8 pins. The
following lists the functions you
can assign to the pins.
• – – – (“– – –”: No function is
assigned.)
•COMPOSITE
•SDI
• HDMI
• OVERSCAN
• NORMAL
• NATIVE
•4:3
•16:9
•TALLY R
•TALLY G
BLUE ONLY
• MONO
•H/V DELAY
•16:9 MARKER
•15:9 MARKER
•14:9 MARKER
•13:9 MARKER
1.85:1 MARKER
2.35:1 MARKER
1.85:1 & 4:3 MARKER
•4:3 MARKER
CENTER MARKER
MARKER MAT HALF
•WFM/ALM
•FLIP V
•FLIP H
•FLIP HV
Notes
If you use the PARALLEL
REMOTE function, you need to
connect cables. For more details,
see page29.
Set MARKER ENABLE
(page 21) to ON to control the
aspect marker and center
marker.
PARALLEL REMOTE:
SERIAL REMOTE: xxxxxxx
MONITOR:
CONTROLLER:
CONNECTION: xxx
REMOTE
SERIAL REMOTE
MONITOR
CONTROLLER
CONNECTION
Selects the mode to be used.
OFF: SERIAL REMOTE does
not function.
ETHERNET: The monitor is
controlled by the command
of Ethernet.
BKM-15R: Sets BKM-15R.
Sets the monitor setting.
MONITOR ID: Sets the ID
of the monitor.
GROUP ID: Sets the group
ID of the monitor.
IP ADDRESS: Sets the IP
address.
SUBNET MASK: Sets the
subnet mask.
(255.255.255.000)
DEFAULT GATEWAY:
Sets the default gateway on
or off.
ADDRESS: Sets the default
gateway.
CANCEL: Selects to cancel
the setting.
CONFIRM: Selects to save
the setting.
Sets the address of the remote
controller.
IP ADDRESS: Sets the IP
address.
SUBNET MASK: Sets the
subnet mask.
(255.255.255.000)
DEFAULT GATEWAY:
Sets the default gateway on
or off.
ADDRESS: Sets the default
gateway.
CANCEL: Selects to cancel
the setting.
CONFIRM: Selects to save
the setting.
Sets the connection of the monitor
and the controller.
PEER TO PEER: for one
to one connection
LAN: for connection via a
network
Submenu Setting