Specifications

AUDIO POWERSPECIFICATIONS

POWER OUTPUT AND TOTAL HARMONIC DISTORTION:

(Models of area code U only)

With 8 ohm loads, both channels driven, from 20 – 20,000 Hz; rated 90 watts per channel minimum RMS power, with no more than 0.09% total harmonic distortion from 250 milliwatts to rated output.

Amplifier section

Models of area code U, CA, CEL, CEK1) Minimum RMS Output Power (8 ohm, 20 Hz – 20 kHz, THD 0.09%)

90 W + 90 W

Stereo Mode Output Power (8 ohm, 1 kHz, THD 1%)

100 W + 100 W

1)Measured under the following conditions:

Area code

Power requirements

U, CA

120 V AC, 60 Hz

 

 

CEL, CEK

230 V AC, 50 Hz

 

 

Frequency response (Analog)

 

10 Hz – 70 kHz

 

+0.5/–2 dB (with BASS =

 

0 dB, TREBLE = 0 dB)

Inputs (Analog)

Sensitivity: 500 mV/

 

50 kohm

 

S/N2): 96 dB

 

(A, 500 mV3))

Outputs (Analog)

 

AUDIO OUT

Voltage: 500 mV/10 kohm

Tone

 

Gain levels

±10 dB, 1 dB step

2)INPUT SHORT (with BASS = 0 dB, TREBLE =

0 dB).

3)Weighted network, input level.

FM tuner section

Tuning range

87.5 – 108.0 MHz

Antenna (aerial)

FM wire antenna (aerial)

Antenna (aerial) terminals

 

75 ohm, unbalanced

Intermediate frequency

 

10.7 MHz

AM tuner section

Tuning range

Area code

Tuning scale

 

10 kHz step

9 kHz step

 

 

 

U, CA

530 –

531 –

 

1,710 kHz

1,710 kHz

 

 

 

CEL, CEK

–

531 –

 

 

1,602 kHz

 

 

 

Antenna (aerial)

Loop antenna (aerial)

Intermediate frequency

 

450 kHz

General

Power requirements

Area code

Power requirements

 

 

U, CA

120 V AC, 60 Hz

 

 

 

 

 

 

CEL, CEK

230 V AC, 50/60 Hz

Additional

 

 

 

 

Power output (DIGITAL MEDIA PORT)

 

DC OUT:

5 V, 0.7 A MAX

Information

Power consumption

 

 

 

 

 

 

 

 

 

 

 

Area code

Power consumption

 

 

 

 

 

U, CA, CEL, CEK

200 W

 

 

 

 

Dimensions (w/h/d) (Approx.)

 

 

430 × 132.5 × 279 mm

 

 

(17 × 5 1/4 × 11 inches)

 

 

including projecting parts

 

 

and controls

 

Mass (Approx.)

6.6 kg (14 lb 9 oz)

 

continued