Others

Symptom

Cause and Remedy

 

 

The LAMP/COVER

• The lamp cover or the air filter cover is detached.

indicator flashes.

c Attach the cover securely (see page 31).

 

 

The LAMP/COVER

• The lamp has reached the end of its life.

indicator lights up.

c Replace the lamp (see page 31).

 

• The lamp becomes a high temperature.

 

c Wait for 60 seconds to cool down the lamp and turn on the

 

power again (see page 24).

 

 

The FAN/TEMP indicator

• The fan is broken.

flashes.

c Consult with qualified Sony personnel.

 

 

The FAN/TEMP indicator

• The internal temperature is unusually high.

lights up.

c Check to see if nothing is blocking the ventilation holes.

 

 

Both the LAMP/COVER

• The electrical system breaks down.

and FAN/TEMP indicators

c Consult with qualified Sony personnel.

light up.

 

 

 

Warning Messages

Use the list below to check the meaning of the messages displayed on the screen.

MessageMeaning and Remedy

Maintenance

 

 

 

 

High temp.!

• Internal temperature is too high.

 

Lamp off in 1 min.

c Turn off the power.

 

 

c Check to see if nothing is blocking the ventilation holes.

 

 

 

 

Frequency is out of range!

• This input signal cannot be projected as the frequency is out of the

 

 

acceptable range of the projector.

 

 

c Input a signal that is within the range of the frequency.

 

 

• The resolution setting of the output signal of a computer is too

 

 

high.

 

 

c Set the setting of output to SVGA (VPL-CS10) or XGA (VPL-

 

 

CX10) (see page 16).

 

 

 

 

Please check INPUT-A

• You have input RGB signal from the computer when INPUT-A in

 

setting.

the SET SETTING menu is set to COMPONENT.

 

 

c Set INPUT-A correctly (see page 30).

 

 

 

 

Please replace the lamp.

• It is time to replace the lamp.

 

 

c Replace the lamp.

 

 

 

 

Caution Messages

Use the list below to check the meaning of the messages displayed on the screen.

Message

Meaning and Remedy

 

 

NO INPUT

• No input signal

 

c Check connections (see page 16).

 

 

Not applicable!

• You have pressed the wrong key.

 

c Press the appropriate key.

 

 

Troubleshooting 35 GB