GEN LOCK
Lets you set the external sync mode.
NORMAL : Makes the HD/VD or VS signal the reference signal according to the external input signal (automatic switching).
R.R1 (restart/reset) : Inputs an external trigger signal twice to control the start of shooting and the output timing. The first signal initiates the charge; the second signal completes the charge and outputs one field of the image. You can also change the charging time for long exposure.
R.R2 – R.R4: Lets you set the charging time and the image output relative to one trigger signal input as given below.
Mode | Charging | Output |
| Trigger |
time |
| pulse | ||
|
|
| ||
|
|
|
|
|
R.R2 | 1 field | 1 field |
| 1 |
|
|
|
|
|
R.R3 | 1 field | 2 fields |
| 1 |
|
|
|
|
|
R.R4 | 2 fields | 2 fields |
| 1 |
|
|
|
|
|
D-SUB
Lets you select the output signal for the RGB/SYNC connector.
VBS : Outputs a composite video signal.
Y/C : Outputs a Y/C signal.
47