Mode Setting
Sample input timing chart 2
EXT HD
EXT VD
Continuous signal: 15.734 kHz
VD interval (T): 262.5 H or more
312.5H or more
T
1/60 1/60
second second
Exposure time for the Odd field
Exposure time for the Even field
Frame Accumulation (Factory setting)
Video output
|
|
|
|
|
|
|
|
| Odd |
| Even image |
|
|
|
|
|
|
|
|
|
| image |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |||||||
| Invalid image | Valid frame image |
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.
Frame image output with a strobe light
The factory setting for this camera is Frame Accumulation. The images obtained when the normal continuous shutter or trigger shutter is used are field images (vertical resolution: 243 lines).
Using a strobe light and Restart/Reset mode, you can obtain bright frame images by synchronizing any strobe light. (Vertical resolution: 485 lines).
Sample input timing chart
EXT HD
EXT VD
Continuous signal: 15.734 kHz
VD: 1/60 sec
Four or more VD pulses are required.
Strobe light
Exposure time for the Odd field
Exposure time for the Even field
Frame Accumulation (Factory setting)
Video output
Odd Even
image image
Invalid image | Valid frame image |
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside. Avoid lighting the scene during the
Note
For best performance, it is recommended that you not flash between VD and VD + 10 H