Mode Setting

Specifications of the Input/Output

Input Phase Specifications of the External HD/VD

5 200

EVEN,

External Non Interlace

100

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

VD

 

 

 

 

 

 

 

 

 

 

 

 

ODD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External HD

 

 

455 (454)

 

 

455 (454)

 

 

 

 

 

 

 

 

 

( ): CCIR

Unit: Clock 1Clk=69.84 nsec (EIA)

70.48 nsec (CCIR)

Make sure that the external HD/VD phases against the standard central phase are as shown in the figure above. Invalid signal input may cause an error in the internal reset.

When you restart/reset the camera or operate the camera by inputting an external trigger shutter pulse, the Vsync signal for the image is output 1 H later from the external VD.

Normal:

HD/VD continuous (EIA/CCIR frequencies: Maintained. Timing: See the above figure.)

Restart/Reset and /External trigger shutter

HD continuous/VD (Reset): Any timing if the phase with HD is within the above range.

Specifications of the WEN Output

 

 

 

 

 

 

 

4.5 V

 

 

250

H(EIA)

 

0 V

 

 

293

H(CCIR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The amplitude level is the typical value when terminated with 10 k.

Specifications of the Trigger Pulse

 

 

 

 

 

4 to 5.0 V

 

 

2 sec

 

 

 

 

 

 

 

 

to

 

 

0 to 1.0 V

 

 

1/4 sec

 

 

 

 

 

 

 

 

 

 

 

Input impedance; 10 kor more.

The voltage and pulse width used are measured at pin 11 of a 12-pin multi-connector on the rear panel.

If you set the trigger pulse with the DIP switches, use the 100 s to 1/4 sec pulse width.

Setting the external shutter speed with the trigger pulse width

Set all DIP switches (1 to 4 on the rear panel) to 0. You can obtain an arbitrary shutter speed by setting the trigger pulse width to the range of 2 sec to 250 msec.

Mode 1 (Non-reset mode)

Mode 2 (Reset mode)

 

 

 

 

 

 

 

 

 

 

 

 

Exposure time = Trigger pulse width + 97 sec (EIA) Trigger pulse width + 120 sec (CCIR)

Notes

The DIP switch 5 position is optional. (The field setting is recommended.) The field setting can obtain a sensitivity that is twice that of the frame setting.

If you input a new trigger pulse before the video signal output for the previous trigger pulse is output completely, an incorrect video signal will be output.