Actual control can be carried out by setting registers from F0F00800 onward.

dddindicates the control value expressed as a 12 bit hexadecimal number.

xxx indicates that any setting made will be ignored.

Brightness control

Address

Data

 

 

 

 

F0F00800

82000ddd

Adjusts the black level.

 

 

 

AE reference control

Address

Data

 

 

 

 

F0F00804

82000ddd

Sets the AE reference value.

 

 

 

Shutter (exposure time) control

Address

Data

 

 

 

 

F0F0081C

82000ddd

Controls shutter using the manually

 

 

set relative value.

 

 

 

 

83000xxx

Sets to AUTO.

 

 

 

 

C2000xxx

Controls shutter using the absolute

 

 

control value.

 

 

 

F0F00970

Indicates an

After F0F0081C has been set to

(See page 25.)

arbitrary value

Absolute value control, set exposure

 

using a 32-bit

time using this register.

 

floating point

 

 

value.

 

 

 

 

Gain control

Address

Data

 

 

 

 

F0F00820

82000ddd

Sets Gain manually.

 

 

 

 

83000xxx

Sets Gain to AUTO.

 

 

 

Pan/Tilt control

Address

Data

 

 

 

 

F0F00884

82000ddd

Sets Pan manually.

 

 

 

F0F00888

82000xxx

Sets Tilt manually.

 

 

 

 

 

Control

Trigger control

 

 

 

 

Address

Data

 

 

 

 

F0F00830

82000000

Sets to Hardware Trigger Mode0.

 

 

 

 

82010000

Sets to Hardware Trigger Mode1.

 

 

 

 

82E00000

Sets to Software Trigger Mode0. *

 

 

 

 

82E10000

Sets to Software Trigger Mode1. *

 

 

 

F0F0062C*

80000000

Outputs a software trigger.

 

 

In Trigger Mode0, automatically reset

 

 

to 0 when exposure ends.

 

 

 

 

00000000

In Trigger Mode1, ends exposure if

 

 

“0” is set.

 

 

 

* These features comply with IIDC v.1.31.

White Balance control (XCD-SX910CR/ X710CR only)

AddressData

F0F0080C

82bbbrrr

Sets R and B Gain.

“bbb” sets B Gain, “rrr” sets R Gain.

Hue (G Gain) control (XCD-SX910CR/ X710CR only)

AddressData

F0F00810

82000ddd

Sets G Gain.

Optical Filter control (Bayer pattern selection) (XCD-SX910CR/X710CR only)

AddressData

F0F0088C

82000ddd

Selects the Bayer pattern.

The following Bayer patterns are available.

Pattern 0

GB R G

Pattern 1

BG G R

Pattern 2

RG G B

Pattern 3

GR B G

XCD-SX910CR/X710CR

 

XCD-SX910UV

24