Control

Step 3

PixelNumber is read out.

TotalByte is read out.

PacketParaINQ is read out.

Sets the packet size.

Error

Check the packet size.

No error

Read F0F10034h. Number of pixels is obtained. (Use this information if required by the software application.)

Read F0F10038-3Ch. Total byte (of effective image) is obtained.

Read F0F10040h. Packet size that can be set is obtained. (1,200 (minimum) and 2,400 (maximum) for this camera.)

Write 09600960h in F0F10044h. (PacketSize = 2400)

Read F0F1007Ch. Check that Bit 9 is not set. If an error occurs, the PacketSize was wrong. Try other settings.

Obtain the number of packets.

Setting completed.

Read F0F10048h. The number of packets per 1 frame is obtained. (The total number of bytes of the data output by the camera output = Packet size number of packets)

Now image transmission is ready. Send a video start command to output images.