3. ELECTRICAL DESCRIPTION

All electrical connections to the module are protected in compliance with the standard air and contact Electrostatic Discharge (ESD).

The module uses the following industry standard connectors:

Sub-D 9 pin female (Main RS232 serial port)

High density 15 pin (Secondary RS232 UART and extended I/O interface)

RJ12 6-way (power supply connector)

RJ9 4-way (handset connector)

SIM card reader

FME male coaxial jack (antenna connector)

3.1Power Conector

An RJ11 6-way connector, as shown and described below, serves means of supplying and controlling d.c. power to the modem.

The supply voltage, VCC, required by the modem is in the range 32V d.c. Application of the supply voltage does not switch the modem on. To do so an additional active-high control signal, TO_IN, must applied for > 0.2s.

A second active-high control signal, HR_IN, can be used to switch modem off when applied for 1 - 2 seconds, or can be used to perform hardware reset when applied for > 3.5s.

TO_IN and HR_IN are referenced to GND (pin 6 on the connector). VCC and GND are reverse polarity and overvoltage protected.

 

 

PIN:

 

Signal

 

Dir

Limits

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

VCC

 

Input

5-32 V DC

 

Positive power input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

VCHARGE

 

Input

 

 

 

 

 

 

 

3

 

HR_IN

 

Input

5 – 36 V

 

Active high control line used to switch off or

 

 

 

 

 

 

 

 

 

 

 

reset the modem

 

 

 

 

 

 

 

 

 

 

 

VIH > 5V, VIL < 2V

 

 

 

 

 

 

 

 

 

 

 

Power off: 1s < t < 2s

 

 

 

 

 

 

 

 

 

 

 

Hard reset: t > 3.5s

 

 

 

 

 

 

 

 

 

 

 

Active high control line used to switch on the

 

 

 

 

4

 

TO_IN

 

Input

5 – 36 V

 

modem

 

 

 

 

 

 

 

 

VIH > 5V, VIL < 2V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power on: t > 0.2s

 

 

 

 

5

 

3.6V out

Output

 

3.6V DC reference signal output. Max 75mA

 

 

 

 

6

 

GND

 

Input

 

 

Negative power (ground) input and return

 

 

 

 

 

 

 

 

path for TO_IN, HR_IN and VCHARGE

 

 

 

 

 

 

 

 

 

 

 

GTR64 Integrators Manual