GTR64 | http://www.matrix.es/GTR64 |
3. ELECTRICAL DESCRIPTION
All electrical connections to the module are protected in compliance with the standard air and contact Electrostatic Discharge (ESD).
The module uses the following industry standard connectors:
•
•High density 15 pin (Secondary RS232 UART and extended I/O interface)
•RJ12
•RJ9
•SIM card reader
•FME male coaxial jack (antenna connector)
3.1Power Conector
An RJ11
The supply voltage, VCC, required by the modem is in the range 32V d.c. Application of the supply voltage does not switch the modem on. To do so an additional
A second
TO_IN and HR_IN are referenced to GND (pin 6 on the connector). VCC and GND are reverse polarity and overvoltage protected.
|
| PIN: |
| Signal |
| Dir | Limits |
| Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
| VCC |
| Input |
| Positive power input |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 |
| VCHARGE |
| Input |
|
|
|
|
|
|
| 3 |
| HR_IN |
| Input | 5 – 36 V |
| Active high control line used to switch off or |
|
|
|
|
|
|
|
|
|
|
| reset the modem |
|
|
|
|
|
|
|
|
|
|
| VIH > 5V, VIL < 2V |
|
|
|
|
|
|
|
|
|
|
| Power off: 1s < t < 2s |
|
|
|
|
|
|
|
|
|
|
| Hard reset: t > 3.5s |
|
|
|
|
|
|
|
|
|
|
| Active high control line used to switch on the |
|
|
|
| 4 |
| TO_IN |
| Input | 5 – 36 V |
| modem |
|
|
|
|
|
|
|
| VIH > 5V, VIL < 2V |
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Power on: t > 0.2s |
|
|
|
| 5 |
| 3.6V out | Output |
| 3.6V DC reference signal output. Max 75mA |
|
| ||
|
| 6 |
| GND |
| Input |
|
| Negative power (ground) input and return |
|
|
|
|
|
|
|
| path for TO_IN, HR_IN and VCHARGE |
|
| |||
|
|
|
|
|
|
| |||||
|
| GTR64 Integrators Manual | V.1.2 | Pag. 13 |
|
|
Preliminary. Subject to change without prior notice