LBI-38965

Configuration Tips

If all 16 ports of a terminal server are needed for System Manager interface, first configure 15 of them using a “dumb” terminal connected to port 1. Port 1 (configuration port) may then be re-assigned to a remote port, accessible via a telnet connection. Telnet into the terminal server on the OVERRIDE port number, and reconfigure port 1 as required. Refer to the Emulex Terminal Server user’s manual for additional information on server configuration via a telnet connection.

The up arrow on a VT100 can be used to recall commands to the terminal server, allowing the user to reissue the same command to each port on the server by only changing port_no.

NOTE

The push button switch (marked default) on the front of the Emulex P2516 terminal server will erase all configuration information in the terminal server and return it to the factory default state. Do not use this switch to reset the terminal server. Cycle power or issue the “Initialize server” command from the server configuration port to restart the terminal server.

Ericsson GE Mobile Communications Inc.

Mountain View Road Lynchburg Virginia 24502

Printed in U.S.A.

33

Page 33
Image 33
Sony Ericsson LBI-38965 installation manual Configuration Tips