LBI-38965

For each site defined in the CAL.DAT file, configure the associated port on the terminal server as follows:

Server>> change port

port_no

access remote

Server>> change port

port_no

type softcopy

Server>>

change

port

port_no

autobaud disabled

Server>>

change

port

port_no

speed 19200

Server>> change service PORT_<port_no> <TCP port_no> port port_no telnet disabled Server>> change port port_no queuing disabled

Server>> change port port_no flow control disabled

TCP port_no is the value defined in CAL.DAT for a particular site.

EXAMPLE:

Assume that the file CAL.DAT has the following two site entries: System Manger site 2 is connected to port 3 on the distribution panel, and System Manager site 10 is connected to port 6 on the distribution panel.

SITE.02.PASSWD

SITE02

 

SITE.02.IP

147.117.37.10

#Terminal server IP address

SITE.02.PORT

5002

#TCP port_no used for site 2

SITE.10.PASSWD

SITE10

 

SITE.10.IP

147.117.37.10

 

SITE.10.PORT

5010

#TCP port_no used for site 10

Inserting the information below would configure the terminal server for the values shown above.

Server>> change port 3 access remote

Server>> change port 3 type softcopy

Server>> change port 3 autobaud disabled

Server>> change port 3 speed 19200

Server>> change service PORT_3 5002 port 3 telnet disabled

Server>> change port 3 queuing disabled

Server>> change port 3 flow control disabled

Server>> change port 6 access remote

Server>> change port 6 type softcopy

Server>> change port 6 autobaud disabled

Server>> change port 6 speed 19200

Server>> change service PORT_6 5010 port 6 telnet disabled

Server>> change port 6 queuing disabled

Server>> change port 6 flow control disabled

After completing the configuration, reconnect the Ethernet LAN connection to the terminal server. If a second terminal server is installed, repeat the procedure above.