6 | Thermostat |
| Chart - HP |
HP23 Two Stage H/P - H*5B, YZE - w/Two Stage Furnace, 2 Stage Cooling Ready - PT8/9, (F,L)*8/9T, (G,L)*8/9T,
| THERMOSTAT | THERMOSTAT | THERMOSTAT |
|
|
|
| TWO STAGE |
| ||
| *PP32U70124 | *DN22H00124 | *PP32U71124 |
|
| COOLING READY |
|
| HEAT PUMP |
| |
|
| *DP22U70124 | *PP32U72124 |
|
| FURNACE CONTROL |
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| C | C | C |
|
|
| C |
|
| C |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| Y | Y1 | Y1 |
|
|
| Y1 |
|
| Y1 |
|
| First Stage Heat/Cool | First Stage Heat/Cool | First Stage Heat/Cool |
|
| First Stage Cool |
|
| First Stage Heat/Cool |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| RC |
|
|
|
|
| Y/Y2 |
|
| Y2 OUT |
|
|
|
|
|
| Single/Second Stage Cool |
|
| Second Stage Cool Output |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| R | R | R |
|
|
| R |
|
| R |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| E |
|
|
|
|
| W/W1 |
|
| W1 OUT |
|
| Emergency Heat |
|
|
|
| Single/First Stage Heat |
|
| First Stage Auxiliary Heat Output |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DHM |
|
|
| W2 |
|
| W2 OUT |
|
|
|
| Dehumidistat |
|
| Second Stage Heat |
|
| Second Stage Auxiliary Heat Output |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| G | G | G |
|
|
| G |
|
|
|
|
| Fan | Fan | Fan |
|
|
| Fan |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| O/B | O | O |
|
|
|
|
|
| O |
|
| Reversing Valve | Reversing | Reversing |
|
|
|
|
|
| Reversing |
|
|
|
|
|
|
|
|
|
|
|
|
|
| L | L | L |
|
|
|
|
|
| X/L |
|
| Malfunction Light | Malfunction Light | Malfunction Light |
|
|
|
|
|
| Malfunction Light |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Y2 | Y2 | Y2 |
|
|
|
|
|
| Y2 |
|
| Second Stage Heat/Cool | Second Stage Heat/Cool | Second Stage Heat/Cool |
|
|
|
|
|
| Second Stage Heat/Cool |
|
|
|
|
|
|
|
|
|
|
|
|
|
| AUX | E/W1 | E/W1 |
|
|
|
|
|
| W |
|
| Auxiliary Heat | First Stage Auxiliary Heat | First Stage Auxiliary Heat |
|
|
|
|
|
| Auxiliary Heat |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| W2 | W2 |
|
|
|
|
|
|
|
|
|
| Second Stage Auxiliary Heat | Second Stage Auxiliary Heat |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HM |
|
|
|
|
|
| BSG |
|
|
|
| Humidistat |
|
|
|
|
|
| Bonnet Sensor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Bonnet Sensor |
|
| BS |
|
|
|
|
|
|
|
| (Optional) |
|
| Bonnet Sensor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Unitary Products Group
Thermostat Installer Setup Number 0170 | Selection of GAS/ELEC switch on | Step 1 of Thermostat User Configuration | |
- System Type - must be set to | |||
thermostat not necessary | Menu must be set to Heat Pump 2 | ||
12 - 3 Heat/2 Cool Heat Pump | |||
|
| ||
|
|
| |
Thermostat Installer Setup Number 0190 - | Step 1 of Thermostat User |
| |
Reversing Valve (O/B) Operation - must be set to 0 | Configuration Menu must be |
| |
- O/B Terminal Energized in Cooling | set to Heat Pump 2 |
| |
|
|
|
Thermostat Installer Setup Number 0200
-Backup Heat Source - must be set to 1 - Heat Pump Backup Heat Source is Fossil Fuel
Thermostat Installer Setup Number 0210 -
External Fossil Fuel Kit - must be set to 0 -
External Fossil Fuel Kit is Controlling
Heat Pump Backup Heat
24V HUMIDIFIER
(Optional)
Set W2 Delay on furnace to OFF
Change FFuel Jumper on
Heat Pump to ON