THERMOSTAT

Unitary Products

Thermostat Chart

Group

- AC

5

AC9 2 Stage Scroll A/C w/2 Stage Furnace, 2 Stage Cooling Ready- PT8/9; (F,L)*8/9T, (G,L)*8/9T, XYG8S-*, XYF8S-*, XYG9S-*, XYF9S-*

 

THERMOSTAT

THERMOSTAT

THERMOSTAT

THERMOSTAT

THERMOSTAT

 

2 STAGE PSC

 

 

TWO STAGE

 

*DN22U00124

*PP32U70124

*DN22C00124

*DP22U70124

*PP32U71124

 

FURNACE CONTROL

 

 

AIR CONDITIONING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*PP32U72124

 

 

 

 

 

 

 

 

 

C

C

C

C

C

 

C

 

 

 

C

 

 

 

24-Volt Common

24-Volt Common

24-Volt Common

24-Volt Common

24-Volt Common

 

24-Volt Common

 

 

24-Volt Common

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

Y

Y

Y1

Y1

 

Y1

 

 

 

Y1

 

 

 

First Stage Cool

First Stage Cool

First Stage Cool

First Stage Cool

First Stage Cool

 

First Stage Cool

 

 

First Stage Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y2

Y2

Y2

Y2

Y2

 

Y/Y2

 

 

 

Y2

 

 

 

 

Single/Second Stage

 

 

 

 

 

 

Second Stage Cool

Second Stage Cool

Second Stage Cool

Second Stage Cool

Second Stage Cool

 

 

 

Second Stage Cool

 

 

 

 

Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

R

R

R

R

 

R

 

 

 

R

 

 

 

24-Volt Hot (Heat XFMR)

24-Volt Hot (Heat XFMR)

24-Volt Hot

24-Volt Hot

24-Volt Hot

 

24-Volt Hot

 

 

24-Volt Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RC

RC

 

 

 

 

 

 

 

 

 

 

 

 

24-Volt Hot (Cool XFMR)

24-Volt Hot (Cool XFMR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E/W1

E/W1

W

E/W1

E/W1

 

W/W1

 

 

 

 

 

 

 

First Stage Heat

First Stage Heat

First Stage Heat

First Stage Heat

First Stage Heat

 

Single/First Stage Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W2

W2

W2

W2

W2

 

W2

 

 

 

 

 

 

 

Second Stage Heat

Second Stage Heat

Second Stage Heat

Second Stage Heat

Second Stage Heat

 

Second Stage Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

G

G

G

G

 

G

 

 

 

 

 

 

 

Fan

Fan

Fan

Fan

Fan

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

Comfort Alert

 

 

 

 

 

 

 

Malfunction Light

 

 

 

 

Interface

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HM

 

 

 

 

 

 

 

 

 

 

 

 

 

Humidistat

 

 

 

 

 

24V HUMIDIFIER

 

 

 

 

 

 

 

 

 

 

 

(Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection of the "C" Termainal,

Connection of the "C" Termainal,

Connection of the "C"

Connection of the "C"

Step 1 of Thermostat User

 

 

 

 

 

 

 

 

 

Termainal, 24-Volt Common,

Termainal, 24-Volt Common,

 

 

 

 

 

 

 

 

 

24-Volt Common, is optional

24-Volt Common, is optional

Configuration Menu must be set

 

 

 

 

 

 

 

 

 

is optional when used with

is optional when used with

 

 

 

 

 

 

 

 

 

when used with batteries

when used with batteries

to MLTI STG

 

 

 

 

 

 

 

 

 

batteries

batteries

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat Installer Setup

Thermostat Installer Setup

 

Step 1 of Thermostat User

Step 16 of Thermostat User

 

 

 

 

 

 

 

 

 

Number 1 - System Type -

Number 0170 - System Type -

 

Configuration Menu must be set

 

 

 

 

 

 

 

 

 

 

Configuration Menu must be

 

 

 

 

 

 

 

 

 

must be set to 6 -

must be set to 8 - 2 Heat/2 Cool

 

to ON to use Comfort Alert

 

 

 

 

 

 

 

 

 

 

set to MS 2

 

 

 

 

 

 

 

 

 

2 Heat/2 Cool Conventional

Multistage Conventional

 

Features

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat Installer Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

Number 15 - Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

Protection - must be set to 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in the Product

For additional

 

Catalog Section.

connection diagrams

 

 

for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com

246782-YTG-B-0407

Page 5
Image 5
York PT9 warranty Thermostat, Stage Psc, Two Stage, Air Conditioning