COUNTER GRIDDLE INSTALLATION
OPERATORS MANUAL 1182629 REV 2PAGE 9
INSTALLATION
Step 2b: Installation Directly on a Non-Combustible Countertop Surface
The griddle may be installed directly onto a flat NON-COM BUSTIBLE surface, as follows:
1. Place the griddle in the position that it will be used. Lift the griddle only from the ends, never fr om the
middle!
2. Connect the gas supply (see Step 4 on page 16), then return to th is procedure.
3. Check that the griddle is in the position you want it to be in.
4. Seal the griddle to the countertop using G.E. or Dow Corning RTV, or the equivalent (as shown in Fig ure
4 below). Consult local codes for exact requirements. A small bead of RTV around all four bottom
edges should be adequate. Open the front door to seal along the front edge of the frame.
5. Go on to Step 5 on page 17.

Figure 4