NOTE: This does not mean that SWTBUG® is equipped with a binary loader-only certain SWTPC binary tapes that contain a special binary loader (in ASCII) will work correctly.

To load the tape simply follow the instructions given for loading an ASCII tape, but keep the reader locked on.

SPECIAL NOTES ON USING AN ACIA AND PROGRAM MODIFICATIONS

Many available 6800 programs written for MIKBUG® assume that a PIA type MP-C control interface is being used and may address this port directly. When using an ACIA type interface, these references need to be changed. For example, some programs, such as BASIC and CORES, poll the PIA periodically to see if a character has been typed in. This is done in order to kick out of a loop or a print sequence. (BASIC uses CTL..C. and CO-RES uses CTL..X.) The source statements that do this usually take the following form:

B6 8004

LDA A PIAD

LOAD A FROM DATA REG.

2B 03

BMI PRINT

BRANCH IF NOT CHAR. SEEN

7E XX XX

JMP READY or RESTART

 

PRINT REMAINDER OF SEQUENCE

To change to a MP-S serial interface, this code can sometimes be replaced as follows;

LDA A PIAD à

ASR A

SEE IF CHAR. LOADED

BMI PRINT à

BCS PRINT

BRANCH IF CHAR. INPUT

 

JMP READY

 

 

PRINT REMAINDER OF SEQUENCE

Before modifying any programs on your own, you should have a working knowledge of SWTBUG'S ACIA input routine, ACIA operation, and your particular program. The following is a list of patches to some SWTPC supplied programs.

BLKJAK - SWTPC 6800 Black Jack Program

 

 

LOCATION

DATA

0270

7E 064A

0647

7E

026D

064A

B6 E008

064D

27 08

064F

B6

8004

0652

2B F3

0654

7E

0275

0657

B6

8004

065A

47

 

065B

24EA

065D

20 F5

With the above modifications BLKJAK will be compatible with either an ACIA or PIA type interface.

CO-RES Ver. 1.0 and 1.01 ACIA Modifications

LOCATION

DATA

1682

47

1683

24 02

1685

20 A0

BASIC 8K and 4K up to an including Ver. 2.0 cannot be modified for ACIA operation. Later versions should be purchased.