Installation
Location RequirementsSelect a location with a solid floor. Dryers installed in residential garages must be elevated 46 cm (18 inches) above the floor.
No other fuel burning appliance should be installed in the same closet with the dryer.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
The dryer needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing. (Minimum clearances are shown in Figure 10.)
F
|
| 1 |
|
|
|
B |
|
|
|
|
|
|
|
|
|
| 3 (G) |
|
|
|
| E |
|
|
|
| D |
|
|
|
|
| A | **106.7 cm |
|
|
|
|
|
| |
|
|
|
| (42 in.) |
|
|
|
|
|
| F |
A | A | C |
|
|
|
FRONT VIEW | SIDE VIEW |
| 2 | FRONT VIEW | |
|
| ||||
(w/o Closet Door) |
|
|
| (Closet Door) | |
|
|
|
|
| D317I |
Area | Free Standing/Alcove Installation |
| Closet Installation |
| |
A | 0 cm (0 in.) |
| 0 cm (0 in.) |
|
|
B | 30.5 cm (12 in.) |
| 30.5 cm (12 in.) |
| |
C | Not Applicable |
| 5.1 cm (2 in.) |
| |
D | 5.1 cm (2 in.) |
| 5.1 cm (2 in.) |
| |
E | 30.5 cm (12 in.) |
| 30.5 cm (12 in.) |
| |
F | Not Applicable |
| 7.6 cm (3 in.) |
| |
G* | Not Applicable |
| 260 cm2/open (40 in2/open) |
|
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)
**NOTE: For new installations, locate top of wall vent 106.7 cm (42 in.) above floor to make venting easier to connect.
1 | Closet Door | 3 | Centered Air Openings |
2 | Outer Wall of Enclosure |
| (2 Openings Minimum) |
Figure 10
18 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 510988 |