
Installation
Exhaust System
IMPORTANT: Keep exhaust duct as short as possible.
NOTE: Be certain old ducts are cleaned before installing your new dryer.
For best drying results, recommended maximum length of exhaust system is shown in table below.
To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally).
NOTE: Weather hood should be installed at least 30.5 cm (12 inches) above the ground.
Number of |
| Weather Hood Type | |
|
| ||
90° Elbows |
|
| |
Recommended | Use Only for Short Run Installations | ||
|
10.2 cm | 10.2 cm |
|
|
|
| |
|
|
|
| |||
(4 in.) |
|
|
|
| ||
(4 in.) | 6.35 cm |
|
| |||
|
|
| ||||
|
| D673I |
|
| ||
|
|
|
|
| ||
|
|
|
| D802I | ||
|
|
|
| |||
|
|
|
|
|
| |
|
|
|
|
|
|
|
Maximum length of 10.2 cm (4 in.) diameter rigid metal duct.
0 | 19.8 m (64 ft.) | 16.8 m (55 ft.) |
|
|
|
1 | 16.8 m (55 ft.) | 14.3 m (47 ft.) |
|
|
|
2 | 14.3 m (47 ft.) | 12.5 m (41 ft.) |
|
|
|
3 | 11.0 m (36 ft.) | 9.1 m (30 ft.) |
|
|
|
4 | 8.5 m (28 ft.) | 6.7 m (22 ft.) |
|
|
|
| Maximum length of 10.2 cm (4 in.) diameter flexible metal duct. | |
|
|
|
0 | 13.7 m (45 ft.) | 10.7 m (35 ft.) |
|
|
|
1 | 10.7 m (35 ft.) | 8.2 m (27 ft.) |
|
|
|
2 | 9.1 m (30 ft.) | 6.4 m (21 ft.) |
|
|
|
3 | 7.6 m (25 ft.) | 5.2 m (17 ft.) |
|
|
|
4 | 6.1 m (20 ft.) | 4.5 m (15 ft.) |
NOTE: Deduct 1.8 m (6 ft.) for each additional elbow.
20 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 510988 |